Register for email alerts and news feeds:
This journal | BMJ Group
rss
British Heart Journal 1988;59:159-167; doi:10.1136/hrt.59.2.159
Copyright © 1988 BMJ Publishing Group Ltd & British Cardiovascular Society

Haemodynamic observations during percutaneous transluminal coronary angioplasty in the presence of synchronised diastolic coronary sinus retroperfusion.

K J Beatt, P W Serruys, P de Feyter, M van den Brand, P D Verdouw, P G Hugenholtz

Catheterisation Laboratory, Thoraxcenter, Erasmus University, Rotterdam, The Netherlands.

Animal studies have demonstrated that synchronised coronary sinus retroperfusion with arterial blood can provide effective perfusion of ischaemic myocardium. Preliminary clinical studies have shown that the technique can also be used with safety in human beings, and in the present study its effectiveness was assessed in three patients undergoing repeated coronary artery occlusions during percutaneous transluminal coronary angioplasty. Arterial blood was removed via an 8F catheter positioned in the femoral artery and delivered by a retroperfusion pumping system to a 7F retroperfusion balloon catheter positioned in the anterior cardiac vein. Ischaemia-related indices were monitored both before and during coronary sinus retroperfusion. These indices included high fidelity left ventricular pressure recordings and pressure derived indices (including velocities of isovolumic contraction and relaxation), as well as electrocardiographic changes and symptoms. Analysis of these variables showed that the ischaemic changes induced during coronary artery occlusion were not prevented by this type of coronary sinus retroperfusion. There was no major complication in any of the patients. It may be that adaptation of the technique or the use of alternative end points will establish a benefit, but further modifications of the delivery system are necessary for effective clinical use.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This article has been cited by other articles:

  • Robinson, M. C., Gross, D. R., Thielmeier, K. A., Hill, B. B., Zeman, W. F. (1997). Development of a Minimally Invasive Technique for Coronary Revascularization in a Porcine Model. Ann. Thorac. Surg. 64: 64-69 [Abstract] [Full Text]  

This Article

Services
Citing Articles
Google Scholar
PubMed
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.