Register for email alerts and news feeds:
This journal | BMJ Group
rss
British Heart Journal 1989;61:46-51; doi:10.1136/hrt.61.1.46
Copyright © 1989 BMJ Publishing Group Ltd & British Cardiovascular Society

Physiological importance of different atrioventricular intervals to improved exercise performance in patients with dual chamber pacemakers.

R J Haskell, W J French

Department of Medicine, University of California, Los Angeles School of Medicine.

To determine the importance of different atrioventricular intervals during exercise in patients with dual chamber pacemakers, seven patients with complete heart block and sinus rhythm were exercised in different pacing modes and atrioventricular intervals: (a) ventricular inhibited (VVI) pacing with no synchronous atrial augmentation or rate responsiveness; (b) atrial synchronous ventricular or DDD pacing with a short mean (SD) atrioventricular interval of 66 (4) ms; and (c) DDD pacing with a long atrioventricular interval of 168 (12) ms. Pacing with a short or long atrioventricular interval gave similar maximum heart rates, oxygen uptake at the anaerobic threshold, end tidal pressure of carbon dioxide or oxygen pulse (a measure of stroke volume). Pacing with either a short or long atrioventricular interval produced a significantly higher oxygen consumption and anaerobic threshold and less lactate production than VVI pacing. During exercise a short atrioventricular interval does not provide a better cardiopulmonary performance than a long atrioventricular interval.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This article has been cited by other articles:

  • Tomczak, C. R., Wojcik, W., Busse, E. F.G., Haennel, R. G. (2005). Phase I and Phase II Oxygen Uptake Kinetics During Atrioventricular Dyssynchrony in Chronotropically Competent Pacemaker Patients. Chest 128: 1782-1789 [Abstract] [Full Text]  
  • Ishikawa, T., Sugano, T., Sumita, S., Nakagawa, T., Hanada, K., Kosuge, M., Kobayashi, I., Kimura, K., Tochikubo, O., Usui, T., Umemura, S. (2001). Optimal atrioventricular delay setting determined by evoked QT interval in patients with implanted stimulus-T-driven DDDR pacemakers. Europace 3: 46-51 [Abstract]  
  • Ishikawa, T., Sugano, T., Sumita, S., Kimura, K., Kikuchi, M., Kosuge, M., Kobayashi, I., Shigemasa, T., Endo, T., Usui, T., Umemura, S. (1999). Relationship between atrioventricular delay, QT interval and cardiac function in patients with implanted DDD pacemakers. Europace 1: 192-196 [Abstract]  

This Article

Services
Citing Articles
Google Scholar
PubMed
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.