Register for email alerts and news feeds:
This journal | BMJ Group
rss
British Heart Journal 1993;70:479-484; doi:10.1136/hrt.70.5.479
Copyright © 1993 BMJ Publishing Group Ltd & British Cardiovascular Society

Use of a remotely controlled mechanical pump for coronary arteriography: a study of radiation exposure and quality implications.

S C Grant, E B Faragher, A P Hufton, D H Bennett

Department of Cardiology, Wythenshawe Hospital, Manchester.

BACKGROUND--Exposure to radiation is a hazard of invasive cardiology. To minimise the risk it is essential to keep the doses received as low as possible. AIM--To assess the effect on cardiologist radiation exposure and the quality of coronary artery opacification of the use of a remotely controlled mechanical pump for coronary arteriography. A secondary aim was to assess any disadvantages and safety. METHODS--319 patients were randomised to have coronary arteriography carried out with contrast injected either by hand or by a remotely controlled mechanical pump. Six cardiologists participated: two catheter laboratories were used and both brachial and femoral approaches were included. The exposure of the cardiologists to radiation was assessed by film badge dosimetry. The badges were worn on the hat. The total time for the procedure, screening time, the dose-area product meter reading, and any complications were recorded for each examination. The quality of arterial opacification was reported on a scale of 0-5. RESULTS--The mean radiation dose per procedure was 0.011 mSv for hand injection of contrast and 0.005 mSv for mechanical injection (p < 0.01). There were no differences in procedure times or screening times. There were no complications attributable to mechanical injection. Arterial opacification was not significantly different in the two groups (4.01 v 4.03 for the left coronary artery, 4.68 v 4.78 for the right coronary artery). The right coronary artery was consistently better opacified than the left by both techniques (4.59 v 3.89, p < 0.001). CONCLUSIONS--Use of a remotely controlled mechanical pump for coronary arteriography reduced cardiologist radiation exposure by half. It was not associated with any inconvenience, expense, or complications and produced arterial opacification at least as good as injection by hand.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This article has been cited by other articles:

  • Martin, C. J. (2009). A REVIEW OF RADIOLOGY STAFF DOSES AND DOSE MONITORING REQUIREMENTS. Radiat Prot Dosimetry 0: ncp168v1-ncp168 [Abstract] [Full Text]  
  • Kim, K. P., Miller, D. L. (2009). MINIMISING RADIATION EXPOSURE TO PHYSICIANS PERFORMING FLUOROSCOPICALLY GUIDED CARDIAC CATHETERISATION PROCEDURES: A REVIEW. Radiat Prot Dosimetry 0: ncp052v1-ncp052 [Abstract] [Full Text]  

This Article

Services
Citing Articles
Google Scholar
PubMed
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.