Outcome of pregnancy in women with valve prostheses.

E. Sbarouni, C. M. Oakley

Department of Medicine (Cardiology), Hammersmith Hospital and Royal Postgraduate Medical School, London.

OBJECTIVE--To study the outcome of pregnancy in women with artificial heart valves treated in major European centres, and to compare the safety and efficacy of different anticoagulant regimens and of mechanical and bioprosthetic valves. DESIGN--Retrospective study. METHOD--The information was obtained by questionnaire sent to all major cardiac centres in Europe sending one cardiologist from each centre a covering letter suggesting that the questionnaire be handed on where appropriate to the most relevant colleague. RESULTS--214 pregnancies were reported in 182 women; 151 pregnancies in 133 women with mechanical valves, and 63 pregnancies in 45 women with bioprostheses. Most women were in New York Heart Association class I or II and in sinus rhythm. 150 women with mechanical valves and 11 (17%) with bioprostheses received anticoagulants during pregnancy. One patient with an aortic valve prosthesis refused to take anticoagulants. Including the spontaneous abortions reported as well as the therapeutic abortions 83% of the pregnancies in women with bioprostheses and 73% in those with mechanical valves resulted in a healthy baby, full term or premature, who did well (NS). The incidence of stillbirths (3% and 6%) and of reported spontaneous abortions are excluded (because they are unlikely to have been fully reported), the success rate was 91% for women with bioprosthetic valves and 84% for women with mechanical valves (NS). 114 (53%) of the women had taken warfarin for some part of the pregnancy (46 (40%) of these during the first trimester) but there were no embryopathies. There were 13 valve thromboses (four fatal), eight embolic events (two fatal), and seven bleeds in women with mechanical valves. Most of these complications occurred with heparin but fatal aortic valve thrombosis occurred in the one woman who refused anticoagulant treatment out of the 151 women with mechanical valves. There were no maternal deaths in the bioprosthesis group but in 17/49 (35%) of these valves functional deterioration led to urgent replacement during pregnancy (two) or soon after. CONCLUSIONS--The outcome of pregnancy was similar for women with mechanical valves or bioprostheses. Warfarin treatment was safe and effective and was not associated with embryopathy. Heparin treatment was associated with more thromboembolic complications and more bleeding complications. Bioprostheses deteriorate rapidly during pregnancy.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This article has been cited by other articles:

  • Jeejeebhoy, F. M. (2009). Prosthetic heart valves and management during pregnancy. cfp 55: 155-157 [Abstract] [Full Text]  
  • 2006 WRITING COMMITTEE MEMBERS, , Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C. Jr, Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O'Gara, P. T., O'Rourke, R. A., Otto, C. M., Shah, P. M., Shanewise, J. S. (2008). 2008 Focused Update Incorporated Into the ACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease): Endorsed by the Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons. Circulation 118: e523-e661 [Full Text]  
  • Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C. Jr, Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O'Gara, P. T., O'Rourke, R. A., Otto, C. M., Shah, P. M., Shanewise, J. S., Nishimura, R. A., Carabello, B. A., Faxon, D. P., Freed, M. D., Lytle, B. W., O'Gara, P. T., O'Rourke, R. A., Shah, P. M. (2008). 2008 Focused Update Incorporated Into the ACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease) Endorsed by the Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, and Society of Thoracic Surgeons. J Am Coll Cardiol 52: e1-e142 [Full Text]  
  • Khamooshi, A. J, Kashfi, F., Hoseini, S., Tabatabaei, M. B, Javadpour, H., Noohi, F. (2007). Anticoagulation for Prosthetic Heart Valves in Pregnancy. Is There an Answer?. Asian Cardiovasc. Thorac. Ann. 15: 493-496 [Abstract] [Full Text]  
  • Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C. Jr, Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O'Gara, P. T., O'Rourke, R. A., Otto, C. M., Shah, P. M., Shanewise, J. S., Smith, S. C. Jr, Jacobs, A. K., Adams, C. D., Anderson, J. L., Antman, E. M., Faxon, D. P., Fuster, V., Halperin, J. L., Hiratzka, L. F., Hunt, S. A., Lytle, B. W., Nishimura, R., Page, R. L., Riegel, B. (2006). ACC/AHA 2006 Guidelines for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease) Developed in Collaboration With the Society of Cardiovascular Anesthesiologists Endorsed by the Society for Cardiovascular Angiography and Interventions and the Society of Thoracic Surgeons. J Am Coll Cardiol 48: e1-e148 [Full Text]  
  • Bonow, R. O., Carabello, B. A., Chatterjee, K., de Leon, A. C. Jr, Faxon, D. P., Freed, M. D., Gaasch, W. H., Lytle, B. W., Nishimura, R. A., O'Gara, P. T., O'Rourke, R. A., Otto, C. M., Shah, P. M., Shanewise, J. S., Smith, S. C. Jr, Jacobs, A. K., Adams, C. D., Anderson, J. L., Antman, E. M., Faxon, D. P., Fuster, V., Halperin, J. L., Hiratzka, L. F., Hunt, S. A., Lytle, B. W., Nishimura, R., Page, R. L., Riegel, B. (2006). ACC/AHA 2006 Practice Guidelines for the Management of Patients With Valvular Heart Disease: Executive Summary: A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the 1998 Guidelines for the Management of Patients With Valvular Heart Disease) Developed in Collaboration With the Society of Cardiovascular Anesthesiologists Endorsed by the Society for Cardiovascular Angiography and Interventions and the Society of Thoracic Surgeons. J Am Coll Cardiol 48: 598-675 [Full Text]  
  • Al Halees, Z. (2006). MECHANICAL VALVES AND PREGNANCY: A CAVEAT. Asian Cardiovasc. Thorac. Ann. 14: 264-264 [Full Text]  
  • Butchart, E. G., Gohlke-Barwolf, C., Antunes, M. J., Tornos, P., De Caterina, R., Cormier, B., Prendergast, B., Iung, B., Bjornstad, H., Leport, C., Hall, R. J.C., Vahanian, A., on behalf of the Working Groups on Valvular Heart, (2005). Recommendations for the management of patients after heart valve surgery. Eur Heart J 26: 2463-2471 [Abstract] [Full Text]  
  • Elkayam, U., Bitar, F. (2005). Valvular Heart Disease and Pregnancy: Part II: Prosthetic Valves. J Am Coll Cardiol 46: 403-410 [Abstract] [Full Text]  
  • Bates, S. M., Greer, I. A., Hirsh, J., Ginsberg, J. S. (2004). Use of Antithrombotic Agents During Pregnancy: The Seventh ACCP Conference on Antithrombotic and Thrombolytic Therapy. Chest 126: 627S-644S [Abstract] [Full Text]  
  • Elkayam, U., Singh, H., Irani, A., Akhter, M. W. (2004). Anticoagulation in Pregnant Women With Prosthetic Heart Valves. J CARDIOVASC PHARMACOL THER 9: 107-115 [Abstract]  
  • Thorne, S A (2004). Pregnancy in heart disease. Heart 90: 450-456 [Full Text]  
  • McLintock, C., North, R. A., White, H. D., Hung, L., Rahimtoola, S. H. (2003). Prosthetic Heart Valves and Pregnancy * Response. Circulation 108 : e159-e160 [Full Text]  
  • Topol, E. J. (2003). Anticoagulation With Prosthetic Cardiac Valves. Arch Intern Med 163: 2251-2252 [Full Text]  
  • The Task Force on the Management of Grown Up Conge, , Task Force members, , Deanfield, J., Thaulow, E., Warnes, C., Webb, G., Kolbel, F., Hoffman, A., Sorenson, K., Kaemmerer, H., Thilen, U., Bink-Boelkens, M., Iserin, L., Daliento, L., Silove, E., Redington, A., Vouhe, P., ESC Committee for Practice Guidelines, , Priori, S., Alonso, M. A., Blanc, J.-J., Budaj, A., Cowie, M., Deckers, J., Fernandez Burgos, E., Lekakis, J., Lindahl, B., Mazzotta, G., Morais, J., Oto, A., Smiseth, O., Trappe, H. J., Document Reviewers, , Deckers, J., Klein, W., Angeles Alonso, M., Blomstrom-Lundqvist, C., de Backer, G., Hradec, J., Mazzotta, G., Parkhomenko, A., Presbitero, P., Torbicki, A. (2003). Management of Grown Up Congenital Heart Disease. Eur Heart J 24: 1035-1084 [Full Text]  
  • Hirsh, J., Fuster, V., Ansell, J., Halperin, J. L. (2003). American Heart Association/American College of Cardiology Foundation guide to warfarin therapy. J Am Coll Cardiol 41: 1633-1652 [Full Text]  
  • Hirsh, J., Fuster, V., Ansell, J., Halperin, J. L. (2003). American Heart Association/American College of Cardiology Foundation Guide to Warfarin Therapy. Circulation 107: 1692-1711 [Full Text]  
  • Ginsberg, J. S., Chan, W. S., Bates, S. M., Kaatz, S. (2003). Anticoagulation of Pregnant Women With Mechanical Heart Valves. Arch Intern Med 163: 694-698 [Abstract] [Full Text]  
  • Hung, L., Rahimtoola, S. H. (2003). Prosthetic Heart Valves and Pregnancy. Circulation 107: 1240-1246 [Full Text]  
  • Srivastava, A. K, Gupta, A. K, Singh, A. V, Husain, T. (2002). Effect of Oral Anticoagulant During Pregnancy With Prosthetic Heart Valve. Asian Cardiovasc. Thorac. Ann. 10: 306-309 [Abstract] [Full Text]  
  • Vitale, N., De Feo, M., Cotrufo, M. (2002). Anticoagulation for prosthetic heart valves during pregnancy: the importance of warfarin daily dose. Eur. J. Cardiothorac. Surg. 22: 656-656 [Full Text]  
  • Al-Lawati, A. A.M., Venkitraman, M., Al-Delaime, T., Valliathu, J. (2002). Pregnancy and mechanical heart valves replacement; dilemma of anticoagulation. Eur. J. Cardiothorac. Surg. 22: 223-227 [Abstract] [Full Text]  
  • HANANIA, G. (2001). Management of anticoagulants during pregnancy. Heart 86: 125-126 [Full Text]  
  • Oles, D., Berryessa, R., Campbell, K., Bhatti, M. A. (2001). Emergency redo mitral valve replacement in a 27-year-old pregnant female with a clotted prosthetic mitral valve, preoperative fetal demise and postoperative ventricular assist device: a case report. Perfusion 16: 159-164 [Abstract]  
  • Ginsberg, J. S., Greer, I., Hirsh, J. (2001). Use of Antithrombotic Agents During Pregnancy. Chest 119 : 122S-131S [Full Text]  
  • Yamak, B., Emir, M., Ulus, T. A, Aksoyek, A., Iscan, Z., Katircioglu, S F., Tasdemir, O., Yamak, B., Emir, M., Ulus, T. A, Aksoyek, A., Iscan, Z., Katircioglu, S F., Tasdemir, O. (2000). Pregnancy With St. Jude Medical Mitral Valve Prosthesis. Asian Cardiovasc. Thorac. Ann. 8: 127-129 [Abstract] [Full Text]  
  • Nelson-Piercy, C., Rosenthal, E., Harding, K., Bewley, S. (2000). Routine elective cesarean section is not justified for women with mechanical heart valves. J Am Coll Cardiol 35: 1365-1365 [Full Text]  
  • Chan, W. S., Anand, S., Ginsberg, J. S. (2000). Anticoagulation of Pregnant Women With Mechanical Heart Valves: A Systematic Review of the Literature. Arch Intern Med 160: 191-196 [Abstract] [Full Text]  
  • Weiss, B.M, Hess, O.M (2000). Pulmonary vascular disease and pregnancy: current controversies, management strategies, and perspectives. Eur Heart J 21: 104-115  
  • Meschengieser, S S, Fondevila, C G, Santarelli, M T, Lazzari, M A (1999). Anticoagulation in pregnant women with mechanical heart valve prostheses. Heart 82: 23-26 [Abstract] [Full Text]  
  • North, R. A., Sadler, L., Stewart, A. W., McCowan, L. M.E., Kerr, A. R., White, H. D. (1999). Long-Term Survival and Valve-Related Complications in Young Women With Cardiac Valve Replacements. Circulation 99: 2669-2676 [Abstract] [Full Text]  
  • Vitale, N., De Feo, M., De Santo, L. S., Pollice, A., Tedesco, N., Cotrufo, M. (1999). Dose-dependent fetal complications of warfarin in pregnant women with mechanical heart valves. J Am Coll Cardiol 33: 1637-1641 [Abstract] [Full Text]  
  • Messmore, H. L. Jr, Kundur, R., Wehrmacher, W., Scanlon, P. (1999). Anticoagulant Therapy of Pregnant Patients with Prosthetic Heart Valves : Rationale for a Clinical Trial of Low Molecular Weight Heparin. CLIN APPL THROMB HEMOST 5: 73-77 [Abstract]  
  • Emir, M., Uzunonat, G., Yamak, B., Ulus, A T., Gol, M K., Iscan, Z., Katircioglu, S F., Mavitas, B., Tasdemir, O., Bayazit, K. (1998). Effects of Pregnancy on Long-Term Follow-Up of Mitral Valve Bioprostheses. Asian Cardiovasc. Thorac. Ann. 6: 174-178 [Abstract] [Full Text]  
  • Sharma, N., Grover, A., Radotra, B. D. (1998). Prosthetic Cardiac Valve Replacement: Management Problems. Asian Cardiovasc. Thorac. Ann. 6: 179-182 [Abstract] [Full Text]  

This Article

Services
Citing Articles
Google Scholar
PubMed
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.