Register for email alerts and news feeds:
This journal | BMJ Group
rss
Heart 1996;75:509-512; doi:10.1136/hrt.75.5.509
Copyright © 1996 BMJ Publishing Group Ltd & British Cardiovascular Society

Disturbance of peripheral microvascular fluid permeability by the onset of atrioventricular asynchrony in patients with programmable pacemakers.

I. R. Mahy, D. M. Lewis, A. C. Shore, M. D. Penney, L. D. Smith, J. E. Tooke

Department of Vascular Medicine, University of Exeter.

BACKGROUND: In vitro and in vivo evidence suggests that atrial natriuretic peptide can enhance fluid flux from intravascular to extravascular compartments. The relevance of this to human pathophysiology remains unclear. OBJECTIVES: To determine whether a central haemodynamic change associated with increased plasma concentrations of atrial natriuretic peptide produces detectable change in the capillary filtration coefficient in a peripheral microvascular bed. PATIENTS: 12 patients with programmable dual chamber permanent pacemakers. METHODS: Calf capillary filtration coefficient (using a modified plethysmographic technique) and plasma atrial natriuretic peptide concentrations were measured during atrioventricular synchronous and ventricular pacing. RESULTS: Atrioventricular asynchrony was associated with higher mean (SD) concentrations of atrial natriuretic peptide (231.9 (123.1) v 53.5 (38.8) pg/ml) and an increased mean (SD) calf capillary filtration coefficient (4.2 (1.1) v 3.6 (1.1) ml/min.mm Hg.100 ml x 10(-3)), but there was no correlation between the magnitude of the change in these variables in individual patients. CONCLUSIONS: The peripheral capillary filtration coefficient may change in response to altered central haemodynamics. Atrial natriuretic peptide remains one potential candidate mechanism, but other factors are also likely to be involved.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This article has been cited by other articles:

  • Christ, F., Bauer, A., Brugger, D., Niklas, M., Gartside, I. B., Gamble, J. (2000). Description and validation of a novel liquid metal-free device for venous congestion plethysmography. J. Appl. Physiol. 89: 1577-1583 [Abstract] [Full Text]  

This Article

Services
Citing Articles
Google Scholar
PubMed
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.