Register for email alerts and news feeds:
This journal | BMJ Group
rss
Heart 1996;76:269-273; doi:10.1136/hrt.76.3.269
Copyright © 1996 BMJ Publishing Group Ltd & British Cardiovascular Society

Transcatheter occlusion of the arterial duct with Cook detachable coils: early experience.

O. Uzun, S. Hancock, J. M. Parsons, D. F. Dickinson, J. L. Gibbs

Department of Paediatric Cardiology, Killingbeck Hospital, Leeds, United Kingdom.

OBJECTIVE: To assess the effectiveness of modified, controlled release Gianturco coils for transcatheter occlusion of the arterial duct. DESIGN: Prospective study, approved by local medical ethics committee. SETTING: Tertiary paediatric cardiac centre. PATIENTS: 43 patients with left to right shunting through the arterial duct, two of whom had a residual leak after surgical ligation and three had residual shunting after previous Rashkind umbrella implantation. INTERVENTION: Transcatheter delivery of one or more coils to the arterial duct. MAIN OUTCOME MEASURES: Complete occlusion of the arterial duct, based on intention to treat and judged by Doppler echocardiography. Absence of flow disturbance in the branch pulmonary arteries and the descending aorta following the procedure. Assessment of cost of the disposable items used. RESULTS: At a median follow up period of three months complete duct occlusion was achieved in 37 (86%) of the 43 patients. No flow disturbance in the branch pulmonary arteries or the descending aorta was detected in any patient. The median cost of disposable items used during the procedure was 342 pounds. CONCLUSIONS: The Cook detachable coil is an effective and financially attractive alternative to the Rashkind umbrella for closure of the arterial duct.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This article has been cited by other articles:

  • Yan, C, Zhao, S, Jiang, S, Xu, Z, Huang, L, Zheng, H, Ling, J, Wang, C, Wu, W, Hu, H, Zhang, G, Ye, Z, Wang, H (2007). Transcatheter closure of patent ductus arteriosus with severe pulmonary arterial hypertension in adults. Heart 93: 514-518 [Abstract] [Full Text]  
  • Thanopoulos, B D, Tsaousis, G S, Djukic, M, Al Hakim, F, Eleftherakis, N G, Simeunovic, S D (2002). Transcatheter closure of high pulmonary artery pressure persistent ductus arteriosus with the Amplatzer muscular ventricular septal defect occluder. Heart 87: 260-263 [Abstract] [Full Text]  
  • Magee, A.G, Huggon, I.C, Seed, P.T, Qureshi, S.A, Tynan, M, on behalf of the Association for European Paediatr, (2001). Transcatheter coil occlusion of the arterial duct. Results of the European Registry. Eur Heart J 22: 1817-1821 [Abstract]  
  • Thanopoulos, B. D., Hakim, F. A., Hiari, A., Goussous, Y., Basta, E., Zarayelyan, A. A., Tsaousis, G. S. (2000). Further experience with transcatheter closure of the patent ductus arteriosus using the Amplatzer duct occluder. J Am Coll Cardiol 35: 1016-1021 [Abstract] [Full Text]  
  • Sreenivas Kumar, A., Kapoor, A., Sinha, N., Shahi, M., Goel, P. K., Radhakrishnan, S., Srivastava, S. (1999). Percutaneous Occlusion of Patent Ductus Arteriosus with Controlled-Release Coil. Asian Cardiovasc. Thorac. Ann. 7: 204-208 [Abstract] [Full Text]  
  • Rao, P. S., Kim, S. H., Choi, J.-Y., Rey, C., Haddad, J., Marcon, F., Walsh, K., Sideris, E. B. (1999). Follow-up results of transvenous occlusion of patent ductus arteriosus with the buttoned device. J Am Coll Cardiol 33: 820-826 [Abstract] [Full Text]  
  • Uzun, O, Veldtman, G R, Dickinson, D F, Parsons, J M, Blackburn, M E C, Gibbs, J L (1999). Haemolysis following implantation of duct occlusion coils. Heart 81: 160-161 [Abstract] [Full Text]  
  • Gamillscheg, A, Beitzke, A, Stein, J I, Rupitz, M, Zobel, G, Rigler, B (1998). Transcatheter coil occlusion of residual interatrial communications after Fontan procedure. Heart 80: 49-53 [Abstract] [Full Text]  
  • Uzun, O, Dickinson, D, Parsons, J, Gibbs, J L (1998). Residual and recurrent shunts after implantation of Cook detachable duct occlusion coils. Heart 79: 220-222 [Abstract] [Full Text]  
  • Sullivan, I. D (1998). Patent arterial duct: when should it be closed?. Arch. Dis. Child. 78: 285-287 [Full Text]  

This Article

Services
Citing Articles
Google Scholar
PubMed
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.