Transcatheter closure of large patent ductus arteriosus (> or = 4 mm) with multiple Gianturco coils: immediate and mid-term results.
Department of Pediatrics, Floating Hospital for Children at New England Medical Center, Tufts University School of Medicine, Boston, Massachusetts, USA.
OBJECTIVE: To assess the immediate and mid-term results of transcatheter closure of patent ductus arteriosus (PDA) > or = 4 mm with multiple Gianturco coils. (Transcatheter closure of large PDAs using the Rashkind occluder or the buttoned device is associated with a 7-38% incidence of residual shunt.) METHODS: 19 patients (7 male, 12 female) underwent an attempt at anterograde transcatheter closure with multiple Gianturco coils of a large PDA at a median age of 3.8 yr (range 2 weeks-34 yr) and median weight of 14 kg (range 2.3-80 kg). RESULTS: The median PDA diameter at the narrowest segment was 4.3 mm (range 4-7 mm) and the mean (SD) Qp/Qs was 1.9 (0.8). Each patient had left atrial and left ventricular volume overload. A 4F catheter was used to deliver the coils in all patients. There was immediate and complete closure in 16/18; one patient had residual shunt that was closed at a second procedure and the other had spontaneous disappearance of the residual shunt at the six week visit. A short ductus (angiographic type B) in one patient could not be closed. The median number of coils placed at the first attempt to close the ductus was 4 (range 2-6 coils) and the median fluoroscopy time was 40 minutes (range 13-152 minutes). Mild left pulmonary artery stenosis occurred in the two smallest patients. Coil migration to the lung occurred in 3 patients with retrieval of coils in two patients. All procedures but one were done on an outpatient basis. At a median follow up of 1.6 yr (range 2 weeks-2.2 yr) all patients had complete closure with no new complications. CONCLUSIONS: Anterograde transcatheter closure with multiple Gianturco coils is an effective treatment for most patients with large PDA of diameters up to 7 mm. This technique can be performed in small infants on an outpatient basis without the need for general endotracheal anaesthesia.
This article has been cited by other articles:
-
Yan, C, Zhao, S, Jiang, S, Xu, Z, Huang, L, Zheng, H, Ling, J, Wang, C, Wu, W, Hu, H, Zhang, G, Ye, Z, Wang, H
(2007). Transcatheter closure of patent ductus arteriosus with severe pulmonary arterial hypertension in adults. Heart
93: 514-518
[Abstract] [Full Text] -
Galal, M O., Amin, M., Hussein, A., Kouatli, A., Al-Ata, J., Jamjoom, A.
(2005). Left Ventricular Dysfunction after Closure of Large Patent Ductus Arteriosus. Asian Cardiovasc. Thorac. Ann.
13: 24-29
[Abstract] [Full Text] -
Piechaud, J.-F.
(2004). Closing down: transcatheter closure of intracardiac defects and vessel embolisations. Heart
90: 1505-1510
[Full Text] -
Soares, A. M., Aiello, V. D., Andrade, J. L., Kajita, L. J., Soares, J. Jr, Morhy, S. S., Mathias, W. Jr, B. Lopes, A. A., Ramires, J. A.F.
(2004). Doppler flow evaluation can anticipate abnormal left lung perfusion after transcatheter closure of patent ductus arteriosus. Eur Heart J
25: 1927-1933
[Abstract] [Full Text] -
Jacobs, J. P., Giroud, J. M., Quintessenza, J. A., Morell, V. O., Botero, L. M., van Gelder, H. M., Badhwar, V., Burke, R. P.
(2003). The modern approach to patent ductus arteriosus treatment: complementary roles of video-assisted thoracoscopic surgery and interventional cardiology coil occlusion. Ann. Thorac. Surg.
76: 1421-1428
[Abstract] [Full Text] -
Thanopoulos, B D, Tsaousis, G S, Djukic, M, Al Hakim, F, Eleftherakis, N G, Simeunovic, S D
(2002). Transcatheter closure of high pulmonary artery pressure persistent ductus arteriosus with the Amplatzer muscular ventricular septal defect occluder. Heart
87: 260-263
[Abstract] [Full Text] -
Magee, A.G, Huggon, I.C, Seed, P.T, Qureshi, S.A, Tynan, M, on behalf of the Association for European Paediatr,
(2001). Transcatheter coil occlusion of the arterial duct. Results of the European Registry. Eur Heart J
22: 1817-1821
[Abstract] -
Fischer, G, Stieh, J, Uebing, A, Grabitz, R, Kramer, H H
(2001). Transcatheter closure of persistent ductus arteriosus in infants using the Amplatzer duct occluder. Heart
86: 444-447
[Abstract] [Full Text] -
Bilkis, A. A., Alwi, M., Hasri, S., Haifa, A. L., Geetha, K., Rehman, M. A., Hasanah, I.
(2001). The Amplatzer duct occluder: experience in 209 patients. J Am Coll Cardiol
37: 258-261
[Abstract] [Full Text] -
Thanopoulos, B. D., Hakim, F. A., Hiari, A., Goussous, Y., Basta, E., Zarayelyan, A. A., Tsaousis, G. S.
(2000). Further experience with transcatheter closure of the patent ductus arteriosus using the Amplatzer duct occluder. J Am Coll Cardiol
35: 1016-1021
[Abstract] [Full Text] -
Sreenivas Kumar, A., Kapoor, A., Sinha, N., Shahi, M., Goel, P. K., Radhakrishnan, S., Srivastava, S.
(1999). Percutaneous Occlusion of Patent Ductus Arteriosus with Controlled-Release Coil. Asian Cardiovasc. Thorac. Ann.
7: 204-208
[Abstract] [Full Text] -
Duke, C, Chan, K C
(1999). Aortic obstruction caused by device occlusion of patent arterial duct. Heart
82: 109-111
[Abstract] [Full Text] -
Sreeram, N, Tofeig, M, Walsh, K P, Hutter, P
(1999). Lung perfusion studies after detachable coil occlusion of persistent arterial duct. Heart
81: 642-645
[Abstract] [Full Text] -
Sullivan, I. D
(1998). Patent arterial duct: when should it be closed?. Arch. Dis. Child.
78: 285-287
[Full Text]
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.