Quantitative, non-invasive assessment of ventricular septal defect shunt flow by measuring proximal isovelocity surface area on colour Doppler mapping.

S. Kurotobi, T. Sano, T. Matsushita, M. Takeuchi, S. Kogaki, T. Miwatani, S. Okada

Department of Pediatrics, University Medical School, Osaka, Japan.

OBJECTIVE: To determine whether the proximal isovelocity surface area (PISA) method could be applied to estimate the magnitude of ventricular septal defect (VSD) shunt flow. DESIGN: Prospective analysis of clinical, echocardiographic, and angiographic data. SETTING: University hospital. PATIENTS: 14 children with VSD. METHODS: Colour Doppler images of VSD shunt flow were obtained in parasternal long axis view, four chamber view or both, adjusted to provide the best imaging of flow. The VSD shunt flow rate and shunt volume were calculated as follows: shunt flow rate (SFR) = 2 pi r2 V/BSA in ml/s/m2; shunt volume = SFR x shunt duration time. The shunt volume, shunt fraction, and pulmonary to systemic flow ratio (Qp:Qs) were confirmed by cardiac catheterisation. RESULTS: There was a correlation between shunt variables determined by PISA and those by catheterisation, including shunt volume (r = 0.78, P = 0.001) and shunt fraction (r = 0.74, P = 0.003). Qp:Qs was also significantly correlated with SFR (r = 0.79, P = 0.0007). The SFR was significantly different between the four patients with Qp:Qs < 2.0 (mean (SD) 54 (33) ml/s/m2) and the 10 patients with Qp:Qs > 2.0 (186 (69) ml/s/m2) (P = 0.004). CONCLUSIONS: These data suggest that the PISA method is a reliable non-invasive investigation for the quantitative assessment of VSD shunt flow and provides important information for decisions regarding surgical repair.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

Relevant Article

Should clinical cardiologists incorporate the proximal isovelocity surface area (PISA) method into their ever enlarging armamentarium?
S. J. Goldberg
Heart 1997 78: 209-210. [PDF]

This article has been cited by other articles:

  • Lambert, A. S. (2007). Proximal Isovelocity Surface Area Should Be Routinely Measured in Evaluating Mitral Regurgitation: A Core Review. Anesth. Analg. 105: 940-943 [Abstract] [Full Text]  
  • Ishii, M., Hashino, K., Eto, G., Tsutsumi, T., Himeno, W., Sugahara, Y., Muta, H., Furui, J., Akagi, T., Ito, Y., Kato, H. (2001). Quantitative Assessment of Severity of Ventricular Septal Defect by Three-Dimensional Reconstruction of Color Doppler-Imaged Vena Contracta and Flow Convergence Region. Circulation 103: 664-669 [Abstract] [Full Text]  

This Article

Services
Citing Articles
Google Scholar
PubMed
Topic Collections
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.