© 2002 by Heart
CARDIOVASCULAR MEDICINE
Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate
1 Thoraxcenter, Department of Cardiology, Erasmus University Medical Centre, Rotterdam, Netherlands
2 Department of Radiology, Erasmus University Medical Centre
Correspondence to:
Correspondence to:
Dr Koen Nieman, Thoraxcenter Bd 410, Erasmus University Medical Centre Rotterdam, PO Box 2040, Rotterdam 3000 CA, Netherlands;
koennieman{at}hotmail.com
Objective: To evaluate the impact of heart rate on the diagnostic accuracy of coronary angiography by multislice spiral computed tomography (MSCT).
Design: Prospective observational study.
Patients: 78 patients who underwent both conventional and MSCT coronary angiography for suspicion of de novo coronary artery disease (n=53) or recurrent coronary artery disease after percutaneous intervention (n=25).
Setting: Tertiary referral centre.
Methods: Intravenously contrast enhanced MSCT coronary angiography was done during a single breath hold, and ECG synchronised images were reconstructed retrospectively. All coronary segments of
2.0 mm without stents were evaluated by two investigators and compared with quantitative coronary angiography. Patients were classified according to the average heart rate (mean (SD)) into three equally sized groups: group 1, 55.8 (4.1) beats/min; group 2, 66.6 (2.8) beats/min; group 3, 81.7 (8.8) beats/min.
Results: Image quality was sufficient for analysis in 78% of the coronary segments in patients in group 1, 73% in group 2, and 54% in group 3 (p < 0.01). The sensitivity and specificity for detecting significant stenoses (
50% lumen reduction) in these assessable segments were: 97% (95% confidence interval (CI) 84% to 100%) and 96% in group 1; 74% (52% to 89%) and 94% in group 2; and 67% (33% to 90%) and 94% in group 3 (p < 0.05). Accounting for all segments of
2.0 mm, including lesions in non-assessable segments as false negatives, the sensitivity decreased to 82% (28/34 lesions, 95% CI 69% to 91%), 61% (14/23 lesions, 42% to 77%), and 32% (6/19 lesions, 15% to 50%), respectively (p < 0.01).
Conclusions: MSCT allows reliable coronary angiography in patients with low heart rates.
Keywords: spiral computed tomography; coronary artery disease; heart rate
Abbreviations: EBCT, electron beam computed tomography; MSCT; enhanced multislice spiral computed tomography
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
-
Yang, L., Zhang, Z., Fan, Z., Xu, C., Zhao, L., Yu, W., Yan, Z.
(2009). 64-MDCT Coronary Angiography of Patients With Atrial Fibrillation: Influence of Heart Rate on Image Quality and Efficacy in Evaluation of Coronary Artery Disease. Am. J. Roentgenol.
193: 795-801
[Abstract] [Full Text] -
Cademartiri, F., Maffei, E., Mollet, N. R.
(2008). Is dual-source CT coronary angiography ready for the real world?. Eur Heart J
29: 701-703
[Full Text] -
Hamon, M., Morello, R., Riddell, J. W., Hamon, M.
(2007). Coronary Arteries: Diagnostic Performance of 16- versus 64-Section Spiral CT Compared with Invasive Coronary Angiography Meta-Analysis. Radiology
245: 720-731
[Abstract] [Full Text] -
Kroft, L. J. M., de Roos, A., Geleijns, J.
(2007). Artifacts in ECG-Synchronized MDCT Coronary Angiography. Am. J. Roentgenol.
189: 581-591
[Abstract] [Full Text] -
Vanhoenacker, P. K., Heijenbrok-Kal, M. H., Van Heste, R., Decramer, I., Van Hoe, L. R., Wijns, W., Hunink, M. G. M.
(2007). Diagnostic Performance of Multidetector CT Angiography for Assessment of Coronary Artery Disease: Meta-analysis. Radiology
244: 419-428
[Abstract] [Full Text] -
Hur, G., Hong, S. W., Kim, S. Y., Kim, Y. H., Hwang, Y. J., Lee, W. R., Cha, S. J.
(2007). Uniform Image Quality Achieved by Tube Current Modulation Using SD of Attenuation in Coronary CT Angiography. Am. J. Roentgenol.
189: 188-196
[Abstract] [Full Text] -
Herzog, C., Nguyen, S. A., Savino, G., Zwerner, P. L., Doll, J., Nielsen, C. D., Flohr, T. G., Vogl, T. J., Costello, P., Schoepf, U. J.
(2007). Does Two-Segment Image Reconstruction at 64-Section CT Coronary Angiography Improve Image Quality and Diagnostic Accuracy?. Radiology
244: 121-129
[Abstract] [Full Text] -
Rispler, S., Keidar, Z., Ghersin, E., Roguin, A., Soil, A., Dragu, R., Litmanovich, D., Frenkel, A., Aronson, D., Engel, A., Beyar, R., Israel, O.
(2007). Integrated Single-Photon Emission Computed Tomography and Computed Tomography Coronary Angiography for the Assessment of Hemodynamically Significant Coronary Artery Lesions. J Am Coll Cardiol
49: 1059-1067
[Abstract] [Full Text] -
Jones, C. M., Athanasiou, T., Dunne, N., Kirby, J., Aziz, O., Haq, A., Rao, C., Constantinides, V., Purkayastha, S., Darzi, A.
(2007). Multi-Detector Computed Tomography in Coronary Artery Bypass Graft Assessment: A Meta-Analysis. Ann. Thorac. Surg.
83: 341-348
[Abstract] [Full Text] -
Henneman, M M, Schuijf, J D, Jukema, J W, Lamb, H J, de Roos, A, Dibbets, P, Stokkel, M P, van der Wall, E E, Bax, J J
(2006). Comprehensive cardiac assessment with multislice computed tomography: evaluation of left ventricular function and perfusion in addition to coronary anatomy in patients with previous myocardial infarction. Heart
92: 1779-1783
[Abstract] [Full Text] -
Hamon, M., Biondi-Zoccai, G. G.L., Malagutti, P., Agostoni, P., Morello, R., Valgimigli, M., Hamon, M.
(2006). Diagnostic Performance of Multislice Spiral Computed Tomography of Coronary Arteries as Compared With Conventional Invasive Coronary Angiography: A Meta-Analysis. J Am Coll Cardiol
48: 1896-1910
[Abstract] [Full Text] -
Schuijf, J. D., Wijns, W., Jukema, J. W., DeCramer, I., Atsma, D. E., de Roos, A., Stokkel, M. P.M., Dibbets-Schneider, P., van der Wall, E. E., Bax, J. J.
(2006). A Comparative Regional Analysis of Coronary Atherosclerosis and Calcium Score on Multislice CT Versus Myocardial Perfusion on SPECT. JNM
47: 1749-1755
[Abstract] [Full Text] -
Leschka, S., Wildermuth, S., Boehm, T., Desbiolles, L., Husmann, L., Plass, A., Koepfli, P., Schepis, T., Marincek, B., Kaufmann, P. A., Alkadhi, H.
(2006). Noninvasive Coronary Angiography with 64-Section CT: Effect of Average Heart Rate and Heart Rate Variability on Image Quality. Radiology
241: 378-385
[Abstract] [Full Text] -
Lau, G. T., Ridley, L. J., Bannon, P. G., Wong, L. A., Trieu, J., Brieger, D. B., Lowe, H. C., Freedman, B. S., Kritharides, L.
(2006). Lumen Loss in the First Year in Saphenous Vein Grafts Is Predominantly a Result of Negative Remodeling of the Whole Vessel Rather Than a Result of Changes in Wall Thickness. Circulation
114: I-435-I-440
[Abstract] [Full Text] -
Plass, A., Grunenfelder, J., Leschka, S., Alkadhi, H., Eberli, F. R., Wildermuth, S., Zund, G., Genoni, M.
(2006). Coronary artery imaging with 64-slice computed tomography from cardiac surgical perspective.. Eur. J. Cardiothorac. Surg.
30: 109-116
[Abstract] [Full Text] -
Pannu, H. K., Jacobs, J. E., Lai, S., Fishman, E. K.
(2006). Coronary CT angiography with 64-MDCT: assessment of vessel visibility.. Am. J. Roentgenol.
187: 119-126
[Abstract] [Full Text] -
Boll, D. T., Bossert, A. S., Aschoff, A. J., Hoffmann, M. H., Gilkeson, R. C.
(2006). Synergy of MDCT and Cine MRI for the Evaluation of Cardiac Motility. Am. J. Roentgenol.
186: S379-S386
[Abstract] [Full Text] -
Hoffmann, U., Ferencik, M., Cury, R. C., Pena, A. J.
(2006). Coronary CT Angiography. JNM
47: 797-806
[Abstract] [Full Text] -
Peebles, C
(2006). Computed tomographic coronary angiography: how many slices do you need?. Heart
92: 582-584
[Abstract] [Full Text] -
Cademartiri, F., Mollet, N. R., Runza, G., Baks, T., Midiri, M., McFadden, E. P., Flohr, T. G., Ohnesorge, B., de Feyter, P. J., Krestin, G. P.
(2006). Improving Diagnostic Accuracy of MDCT Coronary Angiography in Patients with Mild Heart Rhythm Irregularities Using ECG Editing.. Am. J. Roentgenol.
186: 634-638
[Abstract] [Full Text] -
Herzog, C., Arning-Erb, M., Zangos, S., Eichler, K., Hammerstingl, R., Dogan, S., Ackermann, H., Vogl, T. J.
(2006). Multi-Detector Row CT Coronary Angiography: Influence of Reconstruction Technique and Heart Rate on Image Quality. Radiology
238: 75-86
[Abstract] [Full Text] -
Manghat, N E, Morgan-Hughes, G J, Marshall, A J, Roobottom, C A
(2005). Multidetector row computed tomography: imaging congenital coronary artery anomalies in adults. Heart
91: 1515-1522
[Abstract] [Full Text] -
Donnelly, P M, Higginson, J D S, Hanley, P D
(2005). Multidetector CT coronary angiography: have we found the holy grail of non-invasive coronary imaging?. Heart
91: 1385-1388
[Abstract] [Full Text] -
Kaiser, C., Bremerich, J., Haller, S., Brunner-La Rocca, H. P., Bongartz, G., Pfisterer, M., Buser, P.
(2005). Limited diagnostic yield of non-invasive coronary angiography by 16-slice multi-detector spiral computed tomography in routine patients referred for evaluation of coronary artery disease. Eur Heart J
26: 1987-1992
[Abstract] [Full Text] -
Achenbach, S., Daniel, W. G.
(2005). Computed Tomography of the Coronary Arteries: More Than Meets the (Angiographic) Eye. J Am Coll Cardiol
46: 155-157
[Full Text] -
Lau, G. T., Ridley, L. J., Schieb, M. C., Brieger, D. B., Freedman, S. B., Wong, L. A., Lo, S. K., Kritharides, L.
(2005). Coronary Artery Stenoses: Detection with Calcium Scoring, CT Angiography, and Both Methods Combined. Radiology
235: 415-422
[Abstract] [Full Text] -
Nakanishi, T., Kayashima, Y., Inoue, R., Sumii, K., Gomyo, Y.
(2005). Pitfalls in 16-Detector Row CT of the Coronary Arteries. RadioGraphics
25: 425-438
[Abstract] [Full Text] -
Jongbloed, M. R. M., Dirksen, M. S., Bax, J. J., Boersma, E., Geleijns, K., Lamb, H. J., van der Wall, E. E., de Roos, A., Schalij, M. J.
(2005). Atrial Fibrillation: Multi-Detector Row CT of Pulmonary Vein Anatomy prior to Radiofrequency Catheter Ablation--Initial Experience. Radiology
234: 702-709
[Abstract] [Full Text] -
Schuijf, J. D., Bax, J. J., Jukema, J. W., Lamb, H. J., Vliegen, H. W., van der Wall, E. E., de Roos, A.
(2005). Noninvasive Evaluation of the Coronary Arteries With Multislice Computed Tomography in Hypertensive Patients. Hypertension
45: 227-232
[Abstract] [Full Text] -
Hoffmann, M. H. K., Shi, H., Manzke, R., Schmid, F. T., De Vries, L., Grass, M., Brambs, H.-J., Aschoff, A. J.
(2005). Noninvasive Coronary Angiography with 16-Detector Row CT: Effect of Heart Rate. Radiology
234: 86-97
[Abstract] [Full Text] -
Schuijf, J. D., Bax, J. J., Jukema, J. W., Lamb, H. J., Vliegen, H. W., Salm, L. P., de Roos, A., van der Wall, E. E.
(2004). Noninvasive Angiography and Assessment of Left Ventricular Function Using Multislice Computed Tomography in Patients With Type 2 Diabetes. Diabetes Care
27: 2905-2910
[Abstract] [Full Text] -
Martuscelli, E., Romagnoli, A., D'Eliseo, A., Tomassini, M., Razzini, C., Sperandio, M., Simonetti, G., Romeo, F., Mehta, J.L.
(2004). Evaluation of Venous and Arterial Conduit Patency by 16-Slice Spiral Computed Tomography. Circulation
110: 3234-3238
[Abstract] [Full Text] -
Schlosser, T., Konorza, T., Hunold, P., Kuhl, H., Schmermund, A., Barkhausen, J.o.
(2004). Noninvasive visualization of coronary artery bypass grafts using 16-detector row computed tomography. J Am Coll Cardiol
44: 1224-1229
[Abstract] [Full Text] -
Schoepf, U. J., Becker, C. R., Ohnesorge, B. M., Yucel, E. K.
(2004). CT of Coronary Artery Disease. Radiology
232: 18-37
[Abstract] [Full Text] -
Martuscelli, E., Romagnoli, A., D'Eliseo, A., Razzini, C., Tomassini, M., Sperandio, M., Simonetti, G., Romeo, F.
(2004). Accuracy of thin-slice computed tomography in the detection of coronary stenoses. Eur Heart J
25: 1043-1048
[Abstract] [Full Text] -
Choi, H. S., Choi, B. W., Choe, K. O., Choi, D., Yoo, K.-J., Kim, M.-I., Kim, J.
(2004). Pitfalls, Artifacts, and Remedies in Multi- Detector Row CT Coronary Angiography. RadioGraphics
24: 787-800
[Abstract] [Full Text] -
Budoff, M. J., Achenbach, S., Duerinckx, A.
(2003). Clinical utility of computed tomography and magnetic resonance techniques for noninvasive coronary angiography. J Am Coll Cardiol
42: 1867-1878
[Abstract] [Full Text] -
Pannu, H. K., Flohr, T. G., Corl, F. M., Fishman, E. K.
(2003). Current Concepts in Multi-Detector Row CT Evaluation of the Coronary Arteries: Principles, Techniques, and Anatomy. RadioGraphics
23: S111-125
[Abstract] [Full Text] -
Nieman, K., Cademartiri, F., Lemos, P. A., Raaijmakers, R., Pattynama, P. M.T., de Feyter, P. J.
(2002). Reliable Noninvasive Coronary Angiography With Fast Submillimeter Multislice Spiral Computed Tomography. Circulation
106: 2051-2054
[Abstract] [Full Text]
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.
