Register for email alerts and news feeds:
This journal | BMJ Group
rss
Heart 2003;89:1316-1321; doi:10.1136/heart.89.11.1316
Copyright © 2003 BMJ Publishing Group Ltd & British Cardiovascular Society
Heart 2003;89:1316-1321
© 2003 by BMJ Publishing Group & British Cardiac Society

CARDIOVASCULAR MEDICINE

Prevalence and clinical significance of incidental paraprosthetic valvar regurgitation: a prospective study using transoesophageal echocardiography

A Ionescu1, A G Fraser1, E G Butchart2

1 University of Wales College of Medicine, Cardiff, UK
2 University Hospital of Wales, Cardiff, UK

Correspondence to:
Correspondence to:
Dr A Ionescu
Wales Heart Research Institute, Academic Avenue, Heath Park, Cardiff CF14 4XN, UK; ionescu{at}cf.ac.uk

Objective: To assess the prevalence, mechanisms, and significance of paraprosthetic regurgitation detected incidentally by transoesophageal echocardiography (TOE) in patients after heart valve replacement.

Design: Prospective observational study.

Setting: Tertiary referral centre.

Patients: 360 consecutive patients (mean (SD) age 65.8(9.5) years, 193 women) undergoing elective first ever valve replacement.

Methods: Postoperative and follow up TOE, and tests for haemolysis and anaemia.

Results: There were 243 aortic, 90 mitral, and 27 double valve replacements, using 316 mechanical and 44 tissue valves, giving 270 aortic and 117 mitral valves. One patient with severe paraprosthetic mitral regurgitation underwent immediate reoperation and was excluded from subsequent analyses. Paraprosthetic jets were detected around 16 (6%) of the aortic and 38 (32%) of the mitral valves (p < 0.05) at the postoperative study. Follow up TOE was available for 151 aortic and 67 mitral valves, 0.9 (0.5) years after operation. Paraprosthetic jets were present in 15 (10%) of the aortic and 10 (15%) of the mitral valves (NS). Two thirds of the aortic and a fifth of the mitral jets were new. Paraprosthetic jets were more common in aortic valves in a supra-annular (12 of 88, 14%) than in an intra-annular position (4 or 182, 2%; p < 0.005) and in mitral valves inserted with continuous (36 of 88, 41%) rather than interrupted sutures (2 of 28, 7%; p < 0.001). Lactate dehydrogenase concentration was higher in patients with paraprosthetic jets than in those without (752 (236) v 654 (208) IU/l, p < 0.001). Haemoglobin and haptoglobin concentrations were not different.

Conclusions: Small paraprosthetic leaks are common, are related to surgical factors, are not associated with increased subclinical haemolysis, and are benign during the first year after heart valve replacement.

Keywords: paraprosthetic regurgitation; haemolysis

Abbreviations: CABG, coronary artery bypass grafting; LDH, lactate dehydrogenase; TOE, transoesophageal echocardiography


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This article has been cited by other articles:

  • Azadani, A. N., Jaussaud, N., Matthews, P. B., Ge, L., Guy, T. S., Chuter, T. A.M., Tseng, E. E. (2009). Energy Loss Due to Paravalvular Leak With Transcatheter Aortic Valve Implantation. Ann. Thorac. Surg. 88: 1857-1863 [Abstract] [Full Text]  
  • Detaint, D., Lepage, L., Himbert, D., Brochet, E., Messika-Zeitoun, D., Iung, B., Vahanian, A. (2009). Determinants of Significant Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation: Impact of Device and Annulus Discongruence. J Am Coll Cardiol Intv 2: 821-827 [Abstract] [Full Text]  
  • Piazza, N., Onuma, Y., de Jaegere, P., Serruys, P. W. (2009). Guidelines for reporting mortality and morbidity after cardiac valve interventions--need for a reappraisal?. Ann. Thorac. Surg. 87: 357-358 [Full Text]  
  • Vahanian, A., Iung, B., Piérard, L., Dion, R., Pepper, J. (2009). CHAPTER 21 Valvular Heart Disease. ESC Textbook of Cardiovascular Medicine 2: med-9780199566990-chapter-med-9780199566990-chapter [Abstract] [Full Text]  
  • Moss, R. R., Ivens, E., Pasupati, S., Humphries, K., Thompson, C. R., Munt, B., Sinhal, A., Webb, J. G. (2008). Role of echocardiography in percutaneous aortic valve implantation.. J Am Coll Cardiol Img 1: 15-24 [Abstract] [Full Text]  
  • Enriquez-Sarano, M., Nkomo, V. T., Michelena, H. (2008). Principles and Practice of Echocardiography in Cardiac Surgery. Card Surg Adult 3: 315-348 [Full Text]  
  • Webb, J. G., Pasupati, S., Humphries, K., Thompson, C., Altwegg, L., Moss, R., Sinhal, A., Carere, R. G., Munt, B., Ricci, D., Ye, J., Cheung, A., Lichtenstein, S. V. (2007). Percutaneous Transarterial Aortic Valve Replacement in Selected High-Risk Patients With Aortic Stenosis. Circulation 116: 755-763 [Abstract] [Full Text]  
  • Authors/Task Force Members, , Vahanian, A., Baumgartner, H., Bax, J., Butchart, E., Dion, R., Filippatos, G., Flachskampf, F., Hall, R., Iung, B., Kasprzak, J., Nataf, P., Tornos, P., Torracca, L., Wenink, A., ESC Committee for Practice Guidelines (CPG), , Priori, S. G., Blanc, J.-J., Budaj, A., Camm, J., Dean, V., Deckers, J., Dickstein, K., Lekakis, J., McGregor, K., Metra, M., Morais, J., Osterspey, A., Tamargo, J., Zamorano, J. L., Document Reviewers, , Zamorano, J. L., Angelini, A., Antunes, M., Fernandez, M. A. G., Gohlke-Baerwolf, C., Habib, G., McMurray, J., Otto, C., Pierard, L., Pomar, J. L., Prendergast, B., Rosenhek, R., Uva, M. S., Tamargo, J. (2007). Guidelines on the management of valvular heart disease: The Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology. Eur Heart J 0: ehl428v1-39 [Full Text]  
  • Russell, I. A., Rouine-Rapp, K., Stratmann, G., Miller-Hance, W. C. (2006). Congenital heart disease in the adult: a review with internet-accessible transesophageal echocardiographic images.. Anesth. Analg. 102: 694-723 [Full Text]  
  • Turina, M. (2005). Supra-annular aortic valve replacement with a mechanical prosthesis. MMCTS 2005: 646- [Abstract] [Full Text]  
  • Tallarico, D., Chiavari, P. A., Mollo, P., Miraldi, F., Mazzesi, G. (2005). Mitral paraprosthetic leak diagnosed by transesophageal echocardiography through nasal way. Eur J Echocardiogr 6: 291-293 [Abstract] [Full Text]  

This Article

Services
Citing Articles
Google Scholar
PubMed
Topic Collections
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.