HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
[Advanced]

Heart 2005;91:1294-1298; doi:10.1136/hrt.2004.042549
Copyright © 2005 BMJ Publishing Group Ltd & British Cardiovascular Society

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Right arrowRequest Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yoshitani, H
Right arrow Articles by Yoshikawa, J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yoshitani, H
Right arrow Articles by Yoshikawa, J

CARDIOVASCULAR MEDICINE

Effect of one or more co-morbid conditions on diagnostic accuracy of coronary flow velocity reserve for detecting significant left anterior descending coronary stenosis

H Yoshitani1, M Takeuchi1, K Sakamoto1, T Akasaka2, K Yoshida2, J Yoshikawa3

1 Department of Internal Medicine, Tane General Hospital, Osaka, Japan
2 Department of Internal Medicine and Cardiology, Kawasaki Medical School, Kurashiki, Japan
3 Department of Internal Medicine and Cardiology, Graduate School of Medicine, Osaka City University, Osaka, Japan

Correspondence to:
Correspondence to:
Dr Masaaki Takeuchi
Department of Internal Medicine, Tane General Hospital, 1-2-31 Sakaigawa, Nishi-ku, Osaka 550-0024 Japan; masaaki_takeuchi{at}hotmail.com

Objective: To determine the effect of one or multiple co-morbid conditions on the diagnostic accuracy of coronary flow velocity reserve (CFVR) in a heterogeneous patient population.

Methods: CFVR was measured in the left anterior descending coronary artery (LAD) by transthoracic Doppler echocardiography (TTDE) in 318 consecutive patients before elective coronary angiography. CFVR was calculated as the average peak diastolic velocity during intravenous ATP infusion divided by baseline flow velocity. All patients underwent coronary angiography within 48 hours. Significant LAD stenosis was defined as > 50% luminal narrowing. Diagnostic accuracy of CFVR was analysed according to the type and number of risk factors that may adversely affect microvascular function.

Results: CFVR was measured in 309 patients, of whom 105 were found to have significant LAD stenosis based on coronary angiography. CFVR < 2.0 had a sensitivity of 86% and a specificity of 77% for predicting significant LAD stenosis. Left ventricular hypertrophy (LVH) was the only factor that significantly lowered diagnostic accuracy (61% with LVH v 84% without LVH, p < 0.001). Diagnostic accuracy was not affected by increasing number of risk factors.

Conclusions: The diagnostic accuracy of CFVR by TTDE for detecting significant LAD stenosis remains high in a more clinically relevant population with multiple cardiovascular co-morbidities. Only the presence of LVH adversely affected diagnostic accuracy.


Abbreviations: APDV, average peak diastolic velocity; B, unstandardised regression coefficient; CFVR, coronary flow velocity reserve; LAD, left anterior descending coronary artery; LVH, left ventricular hypertrophy; TTDE, transthoracic Doppler echocardiography

Keywords: coronary flow velocity reserve; microvascular dysfunction; transthoracic Doppler echocardiography







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS REGISTER
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2005 BMJ Publishing Group Ltd & British Cardiovascular Society