Register for email alerts and news feeds:
This journal | BMJ Group
rss
Published Online First: 29 March 2007. doi:10.1136/hrt.2006.103838
Heart 2007;93:1040-1043
Copyright © 2007 BMJ Publishing Group Ltd & British Cardiovascular Society

CARDIAC IMAGING AND NON-INVASIVE TESTING

Use of automatic exposure control in multislice computed tomography of the coronaries: comparison of 16-slice and 64-slice scanner data with conventional coronary angiography

Anja Deetjen1, Susanne Möllmann1, Guido Conradi1, Andreas Rolf1, Axel Schmermund2, Christian W Hamm1, Thorsten Dill1

1 Department of Cardiology/Cardiovascular Imaging, Kerckhoff Heart Center, Bad Nauheim, Germany
2 Cardioangiologisches Zentrum Bethanien, Im Prüfling, Frankfurt, Germany

Correspondence to:
Dr A Deetjen
Department of Cardiology, Katharinenhospital Stuttgart, Kriegsbergstr, 60 70174 Stuttgart, Germany; a.deetjen{at}katharinenhospital.de

ABSTRACT

Objective: To evaluate the radiation-dose-reduction potential of automatic exposure control (AEC) in 16-slice and 64-slice multislice computed tomography (MSCT) of the coronary arteries (computed tomography angiography, CTA) in patients. The rapid growth in MSCT CTA emphasises the necessity of adjusting technique factors to reduce radiation dose exposure.

Design: A retrospective data analysis was performed for 154 patients who had undergone MSCT CTA. Group 1 (n = 56) had undergone 16-slice MSCT without AEC, and group 2 (n = 51), with AEC. In group 1, invasive coronary angiography (ICA) had been performed in addition. Group 3 (n = 47) had been examined using a 64-slice scanner (with AEC, without ECG-triggered tube current modulation).

Results: In group 1, the mean (SD) effective dose (ED) for MSCT CTA was 9.76 (1.84) mSv and for ICA it was 2.6 (1.27) mSv. In group 2, the mean ED for MSCT CTA was 5.83 (1.73) mSv, which signifies a 42.8% dose reduction for CTA by the use of AEC. In comparison to ICA, MSCT CTA without AEC shows a 3.8-fold increase in radiation dose, and the radiation dose of CTA with AEC was increased by a factor of 1.9. In group 3, the mean ED for MSCT CTA was 13.58 (2.80) mSV.

Conclusions: This is the first study to show the significant dose-reduction potential (42.8%) of AEC in MSCT CTA in patients. This relatively new technique can be used to optimise the radiation dose levels in MSCT CTA.

Abbreviations: AEC, automatic exposure control; BSA, body surface area; CaSc, calciumscore scan; CTA, computed tomography angiography; DLP, dose–length product; ECG-TTCM, ECG-triggered tube current modulation; ED, effective dose; HR, heart rate; ICA, invasive coronary angiography; MSCT, multislice computed tomography


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

This article has been cited by other articles:

  • Bastarrika, G., Lee, Y. S., Huda, W., Ruzsics, B., Costello, P., Schoepf, U. J. (2009). CT of Coronary Artery Disease. Radiology 253: 317-338 [Abstract] [Full Text]  
  • Benchimol, D, Nasstrom, K, Shi, X. (2009). Evaluation of automatic exposure control in a direct digital intraoral system. Dentomaxillofac Radiol 38: 407-412 [Abstract] [Full Text]  
  • Mowatt, G, Cook, J A, Hillis, G S, Walker, S, Fraser, C, Jia, X, Waugh, N (2008). 64-Slice computed tomography angiography in the diagnosis and assessment of coronary artery disease: systematic review and meta-analysis. Heart 94: 1386-1393 [Abstract] [Full Text]  
  • Stolzmann, P., Leschka, S., Scheffel, H., Krauss, T., Desbiolles, L., Plass, A., Genoni, M., Flohr, T. G., Wildermuth, S., Marincek, B., Alkadhi, H. (2008). Dual-Source CT in Step-and-Shoot Mode: Noninvasive Coronary Angiography with Low Radiation Dose. Radiology 249: 71-80 [Abstract] [Full Text]  
  • Scheffel, H, Alkadhi, H, Leschka, S, Plass, A, Desbiolles, L, Guber, I, Krauss, T, Gruenenfelder, J, Genoni, M, Luescher, T F, Marincek, B, Stolzmann, P (2008). Low-dose CT coronary angiography in the step-and-shoot mode: diagnostic performance. Heart 94: 1132-1137 [Abstract] [Full Text]  
  • Roberts, W T, Bax, J J, Davies, L C (2008). Cardiac CT and CT coronary angiography: technology and application. Heart 94: 781-792 [Abstract] [Full Text]  
  • Kuon, E. (2008). Radiation exposure in invasive cardiology. Heart 94: 667-674 [Full Text]  

This Article

Services
Citing Articles
Google Scholar
PubMed
Topic Collections
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.