Heart 2008;94:590-596
VALVULAR HEART DISEASE
Three-dimensional characteristics of functional mitral regurgitation in patients with severe left ventricular dysfunction: a real-time three-dimensional colour Doppler echocardiography study
Division of Cardiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea
Jong-Min Song, Division of Cardiology, Asan Medical Center, University of Ulsan College of Medicine, 388-1 Poongnap2-dong, Songpa-gu, Seoul 138-736, South Korea; jmsong{at}amc.seoul.kr
Objectives: We sought to evaluate the three-dimensional (3D) features of functional mitral regurgitation (FMR) and their geometric determinants by real-time 3D colour Doppler echocardiography.
Methods: Real-time 3D colour Doppler echocardiography was performed in 52 patients with severe left ventricular dysfunction. With aliasing velocity set around 40 cm/s, proximal isovelocity surface area (PISA) radius was measured on medial, central and lateral antero-posterior planes at a mid-systole frame, and the largest (PISAmax) was determined. Geometric investigations of the left ventricle and mitral valve were performed.
Results: The distal length from the anterior leaflet angulation on the central plane was significantly longer in the 29 patients (56%) with eccentric PISA than in the 23 patients with central PISA (1.73 (0.44) vs 1.47 (0.33) cm, p<0.05). The 18 patients (35%) with both-sides dominant PISA had a smaller anterior leaflet bending angle (141° (8°) vs 147° (8°), p<0.05) and a longer distal length from the angulation on the central plane (1.80 (0.36) vs 1.51 (0.41) cm, p<0.05) than the remaining 34 patients. The 14 patients (27%) with separate PISAs had smaller PISAmax (0.33 (0.13) vs 0.45 (0.16) cm, p<0.05), and tenting height (0.91 (0.20) vs 1.06 (0.24) cm, p<0.05) and tenting area (2.1 (0.6) vs 2.7 (0.8) cm2, p<0.05) on the central plane than in those with single PISA.
Conclusions: 3D features of FMR are quite diverse. The shape and site of anterior leaflet bending determine the shape of the regurgitant orifice, and small mitral valve tenting generates separate small regurgitant orifices of FMR in patients with severe left ventricular dysfunction.
This article has been cited by other articles:
-
Marwick, T. H, Lancellotti, P., Pierard, L.
(2009). Ischaemic mitral regurgitation: mechanisms and diagnosis. Heart
95: 1711-1718
[Full Text] -
Jungwirth, B., Mackensen, G. B.
(2008). Real-Time 3-Dimensional Echocardiography in the Operating Room. SEMIN CARDIOTHORAC VASC ANESTH
12: 248-264
[Abstract]
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.
