HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH REGISTER
[Advanced]

Heart. Published Online First: 1 April 2008. doi:10.1136/hrt.2007.135475
Copyright © 2008 BMJ Publishing Group Ltd & British Cardiovascular Society

This Article
Right arrow Full Text (Rapid PDF)
Right arrow All Versions of this Article:
hrt.2007.135475v1
hrt.2007.135475v2    most recent
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this link to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Add article to my folders
Right arrow Download to citation manager
Google Scholar
Right arrow Articles by Burwash, I. G
Right arrow Articles by Beanlands, R. S
PubMed
Right arrow PubMed Citation
Right arrow Articles by Burwash, I. G
Right arrow Articles by Beanlands, R. S

Original articles

Myocardial Blood Flow in Patients with Low Flow, Low Gradient Aortic Stenosis: Differences Between True and Pseudo-Severe Aortic Stenosis. Results from the Multicenter TOPAS (Truly or Pseudo-Severe Aortic Stenosis) Study

Ian G Burwash 1*, Mireille Lortie 1, Philippe Pibarot 2, Robert A de Kemp 1, Senta Graf 3, Gerald Mundigler 3, Aliasghar Khorsand 3, Claudia Blais 2, Helmut Baumgartner 3, Jean G Dumesnil 2, Zeineb Hachicha 2, Jean Da Silva 1 and Rob S Beanlands 1

1 University of Ottawa Heart Institute, Canada
2 Laval University, Canada
3 Medical University of Vienna, Austria

* To whom correspondence should be addressed. E-mail: iburwash{at}ottawaheart.ca.

Accepted 27 February 2008


*  Abstract

Background Impairment of myocardial flow reserve (MFR) in aortic stenosis (AS) with normal left ventricular function relates to the hemodynamic severity.

Objectives To investigate whether myocardial blood flow (MBF) and MFR differs in low flow, low gradient AS depending on whether there is underlying true-severe (TSAS) or pseudo-severe AS (PSAS).

Methods In 36 patients with low flow, low gradient AS [effective orifice area (EOA) <1.2cm2 or ≤0.6cm2/m2, mean gradient <40mmHg, ejection fraction ≤40%], dynamic 13N-ammonia PET perfusion imaging was performed at rest (n=36) and during dipyridamole stress (n=20) to quantify MBF and MFR. Dobutamine echocardiography was used to classify patients as TSAS (n=18) or PSAS (n=18) based on the indexed projected EOA at a normal flow rate of 250ml/s (EOAIproj≤ or >0.55cm2/m2).

Results Compared to healthy controls (n=14), patients with low flow, low gradient AS had higher resting MBF (0.83±0.21 vs. 0.69±0.09ml/min/g, p=0.001), reduced hyperemic MBF (1.16±0.31 vs. 2.71±0.50ml/min/g, p<0.001) and impaired MFR (1.44±0.44 vs. 4.00±0.91, p<0.001). Resting MBF and MFR correlated with indices of AS severity in low flow, low gradient AS with the strongest relationship observed for EOAIproj (rs=-0.50, p=0.002 and rs=0.61, p=0.004, respectively). Compared to PSAS, TSAS had a trend to a higher resting MBF (0.90±0.19 vs. 0.77±0.21ml/min/g, p=0.06), similar hyperemic MBF (1.16±0.31 vs. 1.17±0.32ml/min/g, p=NS), but a significantly smaller MFR (1.19±0.26 vs. 1.76±0.41, p=0.003). A MFR <1.8 had an accuracy of 85% for distinguishing TSAS from PSAS.

Conclusions Low flow, low gradient AS is characterized by higher resting MBF and reduced MFR that relates to the AS severity. The degree of MFR impairment differs between TSAS and PSAS and may be of value for distinguishing these entities.








HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH REGISTER
Terms and conditions relating to subscriptions purchased online  ¦  Website terms and conditions  ¦  Privacy policy
Copyright © 2008 BMJ Publishing Group Ltd & British Cardiovascular Society