Register for email alerts and news feeds:
This journal | BMJ Group
rss
Published Online First: 19 January 2007. doi:10.1136/hrt.2007.115295
Heart 2007;93:432-437
Copyright © 2007 BMJ Publishing Group Ltd & British Cardiovascular Society

RAPID COMMUNICATION

Effect of left ventricular endocardial activation pattern on echocardiographic and clinical response to cardiac resynchronization therapy

Jeffrey W H Fung, Joseph Y S Chan, Gabriel W K Yip, Hamish C K Chan, Winnie W L Chan, Qing Zhang, Cheuk-Man Yu

Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong SAR, China

Correspondence to:
Dr J W H Fung
Division of Cardiology, Department of Medicine and Therapeutics, Prince of Wales Hospital, The Chinese University of Hong Kong, Hong Kong, SAR, China; jwhfung{at}cuhk.edu.hk

Accepted 8 January 2007

ABSTRACT

Objective: To explore the left ventricular (LV) electrical activation pattern in heart failure (HF) and its implication to cardiac resynchronization therapy (CRT).

Design and setting: Observational study at the University Teaching Hospital.

Patients: 23 optimally treated patients with HF with New York Heart Association class III, QRS duration >120 ms and LV ejection fraction <35%.

Interventions: The LV endocardial activation pattern and total activation time (Tat) was determined by non-contact mapping and the LV mechanical dys-synchrony was determined by standard deviation (Ts-SD) and maximal difference (Ts-diff) of time to peak systolic contraction (Ts) among 12 LV segments using tissue Doppler imaging before receiving CRT.

Main outcome measures: Correlation between electrical and mechanical dys-synchrony; volumetric responder to CRT at 3 months; HF hospitalisation or death by Kaplan–Meier analysis.

Results: Homogenous (type I, n = 8) and presence of conduction block (type II, n = 15) patterns were identified. Significant correlation between Tat and Ts-SD/Ts-diff was noted only in type II (r = 0.73/0.56, p = 0.002/0.03). Ts-SD and Ts-diff in type II were significantly longer than type I. 12 patients in type II and 2 in type I were CRT responders (p = 0.01). After 487 (447) days, patients with type II pattern had significantly lower risk of HF hospitalisation or death than those with type I (log rank {chi}2 = 5.25; p = 0.02).

Conclusion: Patients with type II LV endocardial activation pattern had a more favourable echocardiographic and clinical response to CRT than those with type I pattern.

Abbreviations: CRT, cardiac resynchronization therapy; HF, heart failure; LV, left ventricular; Tat, total activation time; TDI, tissue Doppler imaging; Ts-diff, maximal difference of the time to peak systolic contraction of the 12 LV segments by tissue Doppler imaging; Ts-SD, standard deviation of the time to peak systolic contraction of the 12 LV segments by tissue Doppler imaging

In recent years, several large-scale randomised controlled trials have confirmed the beneficial role of cardiac resynchronization therapy (CRT) in patients with systolic heart failure (HF) and a wide QRS complex.1–4 The proposed mechanism of benefit by CRT is the improvement of systolic synchronicity between different LV segments.5 However, up to one third of these patients did not respond to CRT when using conventional selection criteria based on QRS duration.1,6,7 In fact, previous studies have shown that prolonged QRS duration on ECG was a poor marker of underlying LV mechanical dys-synchrony.8,9 Search for better selection criteria is necessary to improve the overall response rate to CRT. Currently, LV mechanical dys-synchrony at baseline assessed by tissue Doppler imaging (TDI) is a useful tool to identify the responders after CRT.5,10,11

Although the proposed mechanism of benefit by CRT is the correction of underlying electromechanical abnormality, the relationship between LV electrical activation and mechanical dys-synchrony detected by echocardiography is not clear. Previous mapping studies have shown that the LV activation pattern was variable in these patients.12–14 Lines of conduction block during LV endocardial activation was detected in some of these patients, but its implication on the response to CRT remains undetermined. By means of non-contact LV mapping and TDI, we sought to (1) explore the LV electromechanical property in patients with HF and wide QRS complex and (2) determine the effect of LV endocardial activation pattern on echocardiographic and clinical response to CRT.

METHODS

Patients

This is a prospective study to evaluate the electromechanical property by TDI and non-contact LV mapping and its implication to CRT response in 23 patients. All patients were in sinus rhythm, with LV ejection fraction <35% measured by transthoracic two-dimensional echocardiography, New York Heart Association class III, QRS complex duration >=120 ms on ECG and optimally treated by medical treatment. Clinical and echocardiographic assessment was performed at baseline and 3 months after CRT. Non-contact LV mapping was performed on the same day after CRT implantation in all patients. The study protocol was approved by the local ethics committee and written informed consents was obtained from all participants.

Biventricular device implantation

Biventricular devices were implanted as described previously.1,5 The LV pacing lead was inserted by a transvenous approach through the coronary sinus and was preferentially placed at the lateral or posterolateral cardiac vein. Thirteen patients received the Attain system (Medtronic, Minneapolis, Minnesota, USA) and 10 received the Easytrak over-the-wire lead (Model 4512, Guidant, St Paul, Minnesota, USA). Apart from three patients who received biventricular cardiac defibrillators, all the others received biventricular pacemakers (InSync, InSync III, Contak TR or Contak TR2). The atrioventricular interval was optimised by Doppler echocardiography for maximal transmitral diastolic filling.

Clinical and echocardiographic assessment

Baseline evaluation included New York Heart Association class assessment, 6-min Hall Walk distance, quality of life assessment by Minnesota Living With Heart Failure Questionnaire and ECG. The echocardiographic assessment (Vivid 5 or 7, Vingmed-General Electric), which was performed and analysed by the same cardiologist blinded to the clinical and non-contact mapping information, included measurement of LV dimensions, ejection fraction, LV end-diastolic and end-systolic volumes. Sphericity index was calculated by dividing the maximum short-axis by the maximum long-axis dimension. The severity of mid-systolic mitral regurgitation was assessed by the percentage jet area relative to the left atrial area in the apical 4-chamber view. LV diastolic function was assessed by transmitral Doppler at the tip of mitral valve. TDI studies were also performed to assess myocardial contraction velocity in individual LV segment of the 6-basal and 6-midsegmental model as described previously.5 The myocardial velocity curves were reconstituted offline with the aid of a customised software package (EchoPac V.6.3.6) and the time to peak myocardial systolic velocity in ejection phase (Ts) were measured with reference to the QRS complex. The LV mechanical dys-synchrony were assessed by calculating the standard deviation (Ts-SD) and maximal difference (Ts-diff) of Ts among the 12 LV segments. The baseline evaluation was repeated 3 months after the implantation of the device.

All patients were followed-up regularly in the HF clinic. Echocardiographic responder to CRT was defined as a 10% reduction in LV end-systolic volumes 3 months after CRT.15 The occurrence of cardiovascular events was adjudicated by cardiologists blinded to the echocardiographic findings and LV activation patterns. For HF hospitalisation, the diagnosis of HF was based on clinical symptoms (limitation of activity, fatigue, and dyspnoea or orthopnoea), physical signs (oedema, elevated jugular venous pressure, rales or third heart sound with gallop) and radiological evidence of pulmonary congestion. The composite of HF hospitalisation or death after CRT in patients with different LV activation patterns were compared.

Non-contact LV mapping

The navigation and mapping method by non-contact LV mapping (Ensite 3000, Endocardial Solution, St Jude Medical) has been described in detail.12–14,16 The 64-electrode, non-contact array and a conventional 7F deflectable-tip mapping catheter (Cordis-Webster) were deployed in the LV via the retrograde aortic approach from both femoral arteries.

The definition of LV activation pattern, localisation of earliest and latest LV activation sites, and measurement of total LV activation time (Tat) was based on previous studies.12–14 In brief, the earliest LV breakthrough site was defined as earliest location from which the propagation spread to the rest of LV consistently. The propagation pattern was determined by tracking back in time in the isopotential maps. Two distinct patterns of LV propagation were described previously.12 Homogenous propagation (type I) was defined as (1) no obvious change in propagation direction and (2) absence of line of block throughout the whole LV activation process (fig 1AGo). Conduction block pattern (type II) was defined as the presence of obvious change in propagation direction (also known as U shaped activation13) and the wavefront split and turned around the line of block in the isopotential map (fig 1BGo).12,13,17 The region or line of conduction block, apart from propagation pattern observed in the isopotential maps, was also characterised by morphological features—namely, detection of split potential, gradual emergence of R wave followed by smooth and steep downstroke in the virtual unipolar electrograms across the region, as shown in fig 1CGo.13 The Tat was defined as the time measured from the sites of earliest to the latest activation, at the location with peak negative amplitude for the associated virtual unipolar electrograms. The transeptal activation time was defined as the time difference between the onset of QRS complex on the surface ECG and the earliest LV breakthrough sites detected by non-contact mapping. The estimated transmural activation time was measured from the latest activated sites to the end of the QRS complex.13 The electrophysiologist responsible for the analysis of the mapping results was blinded to the demographic and echocardiographic data.


 

Statistical analysis

Statistical analysis was performed by SPSS V.11.0. Results were expressed as mean (standard deviation (SD)) unless otherwise specified. Comparisons between groups were performed by {chi}2 test, Fisher’s exact test or Student’s t test as appropriate. Clinical and echocardiographic parameters before and 3 months after CRT were compared by paired Student’s t test in each group. Pearson’s correlation analysis was performed between Tat and Ts-SD/Ts-diff. Life table-estimated event-free survival was calculated by Kaplan–Meier curves, wherein the log-rank {chi}2 values were presented. A p value <0.05 was considered significant. All probabilities were two tailed.

RESULTS

All patients had successful CRT implantation and uneventful non-contact LV mapping. In all, 8 patients had type I, and 15 had type II LV endocardial activation pattern. Table 1Go shows the baseline characteristics between patients with type I and II activation patterns. The proportion of patients with non-ischaemic aetiology was higher in type II pattern, but it did not reach statistical significance. There were no significant differences in other baseline characteristics between patients with different activation patterns except that Ts-SD and Ts-diff were significantly longer in patients with type II activation pattern.


 

Electromechanical property

There was no difference in Tat, transeptal and transmural activation time between type I and II activation patterns (table 1Go). The location of lines of block in patients with type II activation was anterior in 7, lateral in 6 and septal in 2. Six patients in type I and 9 in type II had latest activation site at lateral region and others had the latest site at posterior region. The latest sites in type II pattern were all distal to the lines of block. There was no statistical difference in location of latest activation sites between the two patterns. Figure 2Go shows the relationship between Tat and LV mechanical dys-synchrony (Ts-SD/Ts-diff) in different activation patterns. There was significant correlation between Tat and Ts-SD/Ts-diff in patients with type II pattern, but not in those with type I. Ten patients in type II and 5 in type I had the electrode coincided with the latest activation sites.


 

Response to CRT

Table 2Go shows the changes of clinical and echocardiographic parameters in patients with the two activation patterns at baseline and 3 months after CRT. Significant improvements in clinical parameters and LV systolic function after CRT were only observed in those with type II pattern. The overall echocardiographic responder rate was 61%. Most responders were those who had type II pattern (12 with type II vs 2 with type I, p = 0.01). Table 3Go shows that there was no significant difference in demographic parameters between responders and non-responders. The LV lead was located at lateral wall in 9 and posterior wall in 5 among the responders, although it was located at lateral wall in 6 and posterior wall in 3 among the non-responders (p = NS). Using the population-derived cut-off value of Ts-SD >32.6 ms to define significant mechanical dys-synchrony,18,19 12 of 13 patients with type II pattern and significant mechanical dys-synchrony were responders to CRT. Seven patients without significant mechanical dys-synchrony at baseline were not responders to CRT. Three patients with type I, and one with type II died after 3 months of device implantation and all of them had CRT pacemakers. The patient with type II pattern was a responder to CRT, but with out-of-hospital sudden death. The three patients with type I pattern did not respond to CRT and died of pump failure death in hospitals. Figure 3Go showed that, after a mean follow-up of 487 (447) days, patients with type II pattern had a significantly lower risk of HF hospitalisation or death than that of type I (log rank {chi}2 = 5.25; p = 0.02).


 


 


 

DISCUSSION

The key findings of the present study are that two distinct patterns of LV endocardial activation were identified by non-contact mapping in patients with systolic HF and a wide QRS complex on ECG. Patients with type II activation pattern showed a more favourable response to CRT, in terms of improvement in functional status, significant LV reverse remodelling and reduction of clinical events in long-term follow-up, than those with type I pattern.

Electromechanical property in HF

The role of ECG in identifying significant LV electromechanical dys-synchrony in CRT candidates is under challenge in recent years, especially knowing the overall response rate to CRT is only 60–70% when using the ECG criteria for patient selection. Several echocardiographic studies have consistently demonstrated that ECG alone was a poor marker of LV mechanical dys-synchrony.8,9,10 Information about the relationship between electrical activation and mechanical contraction in these CRT candidates is scarce. Previous LV mapping studies mainly focused on the electrical conduction pattern and identified patterns of slow conduction or lines of block without corresponding information of mechanical dys-synchrony.12–14

This study is the first, to our knowledge, to provide unique information about electromechanical property by combining echocardiographic and endocardial mapping data in the same patients receiving CRT. Tat, a parameter that represents the endocardial electrical activation time from the earliest to the latest sites within the LV, had a significant correlation with the echocardiographic markers of mechanical dys-synchrony only in those with type II pattern; and such relationship was not detected in those with type I activation. The significant correlation between Tat and Ts-SD/Ts-diff in patients with type II pattern suggests that the different peak systolic contraction time within the LV may probably be the direct consequence of the presence of conduction delay within the LV. A previous animal study suggested that the later the LV segment is activated, the longer the electromechanical interval is observed.20 It seems that the close link between electrical activation and mechanical contraction is well preserved in patients with type II pattern. It is then logical to postulate that CRT rectifies or corrects the electrical dys-synchrony and leads to favourable electromechanical coupling, synchronised mechanical performance and structural remodelling in these patients.

The reason for the lack of correlation between Tat and Ts-SD/Ts-diff in patients with type I pattern is unclear. It may suggest that the electromechanical coupling may be disrupted or severely impaired in these patients.21 Moreover, Ts-SD/Ts-diff was significantly shorter in patients with type I pattern suggesting the degree of mechanical dys-synchrony in these patients may be less than those with type II pattern. The lack of benefit by CRT in these patients may be due to the loss of close link between electrical activation and mechanical contraction. This may account for the failure by CRT to improve patients with type I pattern, as the culprit disturbance is not the regional conduction delay, but possibly the disrupted electromechanical association.

There was no difference in Tat between type I and II patterns, which was consistent with the similar QRS duration on ECG observed between the two groups at baseline. QRS duration alone fails to delineate the underlying electrical and mechanical dys-synchrony in these patients. The LV endocardial activation pattern, rather than LV total activation time or QRS duration, may be one of the markers for favourable CRT response. In type II pattern, the observed Tat was probably secondary to the regional conduction delay. The reason for similar duration of Tat in type I pattern is not entirely clear based on the current study though it might be related to the homogenously slow electrical propagation velocity within the diseased myocardium.14

Prevalence of different activation patterns in HF

Variation in prevalence of homogenous LV activation was noted in different studies.12–14 Auricchio et al13 reported that all except one patient (23 of 24) had lines of functional conduction blocks. However, Lambiase et al14 reported that 40% patients had homogenous activation, which was close to the prevalence of 35% in the current study. The QRS duration was 156 (27) ms in the Auricchio et al13 (n = 24) study, 164 (29) ms in the Lambiase et al14 (n = 10) report and 139 (18) ms in the current study (n = 23). It seems that the prevalence of conduction block pattern may not have a close relationship with the QRS duration on ECG. The small number of patients involved in these studies may suggest the possibility of selection bias and large-scale studies may help to clarify the issue.

Study limitation

This study is observational and has a small sample size. However, the overall response rate to CRT was 61%, which was similar to the response rate in other large scale studies.1–4 Moreover, the inclusion criteria of the present study were identical to the recommended guidelines so that the cohort was probably a reasonable sample of CRT recipients in general. Another limitation is the invasive nature of non-contact LV mapping. Although all patients had undergone uneventful procedures, it seems not to be feasible to perform LV mapping before CRT implantation in all patients. Nonetheless, the current study provided important insight into the mechanism of benefit by CRT in patients with respect to different endocardial conduction patterns and the relationship between activation patterns and degree of mechanical dys-synchrony. Further studies are necessary to develop non-invasive markers to identify type II LV activation pattern.

Conclusion

Non-contact LV mapping provides information about the effect of baseline LV activation pattern on CRT response. Patients with type II LV activation pattern showed significant improvement in functional status, favourable LV reverse remodelling and lower clinical events when compared to those with type I pattern after CRT, despite similar QRS duration and total LV activation time. Further exploration into the LV electromechanical relationship may enhance our understanding of the pathophysiology in these patients with HF and wide QRS complex.

ACKNOWLEDGEMENTS

We gratefully acknowledge the S K Yee Charity Foundation for the generous donation of CRT devices to some of the participants in this study.

FOOTNOTES

Published Online First 18 January 2007

Competing interests: None.

REFERENCES

  1. Fisher WG, Smith AL, Delurgio DB, et al. MIRACLE Study Group. Multicenter InSync Randomized Clinical Evaluation. Cardiac Resynchronization in Chronic Heart Failure. N Engl J Med 2002;346:1845–53.[Abstract/Free Full Text]
  2. Bristow MR, Saxon LA, Boehmer J, et al. Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. N Engl J Med 2004;350:2140–50.[Abstract/Free Full Text]
  3. Young JB, Abraham WT, Smith AL, et al. Combined cardiac resynchronization and implantable cardioversion defibrillation in advanced chronic heart failure. JAMA 2003;289:2685–94.[Abstract/Free Full Text]
  4. Cleland JG, Daubert JC, Erdmann E, et al. Cardiac Resynchronization-Heart Failure (CARE-HF) Study Investigators. The effect of cardiac resynchronization on morbidity and mortality in heart failure. N Engl J Med 2005;352:1539–49.[Abstract/Free Full Text]
  5. Yu CM, Chau E, Sanderson JE, et al. Tissue Doppler echocardiographic evidence of reverse remodeling and improved synchronicity by simultaneously delaying regional contraction after biventricular pacing therapy in heart failure. Circulation 2002;105:438–45.[Abstract/Free Full Text]
  6. Molhoek SG, Bax JJ, van Erven L, et al. Effectiveness of resynchronization therapy in patients with end-stage heart failure. Am J Cardiol 2002;90:379–83.[CrossRef][Medline]
  7. Bax JJ, Marwick TH, Molhoek SG, et al. Left ventricular dyssynchrony predicts benefit of cardiac resynchronization therapy in patients with end-stage heart failure before pacemaker implantation. Am J Cardiol 2003;92:1238–40.[CrossRef][Medline]
  8. Bleeker GB, Schalij MJ, Molhoek SG, et al. Relationship between QRS duration and left ventricular dyssynchrony in patients with end-stage heart failure. J Cardiovasc Electrophysiol 2004;15:544–9.[Medline]
  9. Molhoek SG, Bax JJ, Boersma E, et al. QRS duration and shortening to predict clinical response to cardiac resynchronization therapy in patients with end-stage heart failure. Pacing Clin Electrophysiol 2004;27:308–13.[CrossRef][Medline]
  10. Yu CM, Zhang Q, Fung JW, et al. A novel tool to assess systolic asynchrony and identify responders of cardiac resynchronization therapy by tissue synchronization imaging. J Am Coll Cardiol 2005;45:677–84.[Abstract/Free Full Text]
  11. Yu CM, Fung JW, Zhang Q, et al. Tissue Doppler imaging is superior to strain rate imaging and postsystolic shortening on the prediction of reverse remodeling in both ischemic and nonischemic heart failure after cardiac resynchronization therapy. Circulation 2004;110:66–73.[Abstract/Free Full Text]
  12. Fung JW, Yu CM, Yip G, et al. Variable left ventricular activation pattern in patient with heart failure and left bundle branch block. Heart 2004;90:17–19.[Abstract/Free Full Text]
  13. Auricchio A, Fantoni C, Regoli F, et al. Characterization of left ventricular activation in patients with heart failure and left bundle-branch block. Circulation 2004;109:1133–9.[Abstract/Free Full Text]
  14. Lambiase PD, Rinaldi A, Hauck J, et al. Non-contact left ventricular endocardial mapping in cardiac resynchronisation therapy. Heart 2004;90:44–51.[Abstract/Free Full Text]
  15. Yu CM, Bleeker GB, Fung JW, et al. Left ventricular reverse remodeling but not clinical improvement predicts long-term survival after cardiac resynchronization therapy. Circulation 2005;112:1580–6.[Abstract/Free Full Text]
  16. Schilling RJ, Peters NS, Davies DW. Mapping and ablation of ventricular tachycardia with the aid of a non-contact mapping system. Heart 1999;81:570–5.[Abstract/Free Full Text]
  17. Bax JJ, Abraham T, Barold SS, et al. Cardiac resynchronization therapy: part 2—issues during and after device implantation and unresolved questions. J Am Coll Cardiol 2005;46:2168–82.[Abstract/Free Full Text]
  18. Yu CM, Fung WH, Lin H, et al. Predictors of left ventricular reverse remodeling after cardiac resynchronization therapy for heart failure secondary to idiopathic dilated or ischemic cardiomyopathy. Am J Cardiol 2003;91:684–8.[CrossRef][Medline]
  19. Yu CM, Lin H, Zhang Q, et al. High prevalence of left ventricular systolic and diastolic asynchrony in patients with congestive heart failure and normal QRS duration. Heart 2003;89:54–60.[Abstract/Free Full Text]
  20. Prinzen FW, Augustijn CH, Allessie MA, et al. The time sequence of electrical and mechanical activation during spontaneous beating and ectopic stimulation. Eur Heart J 1992;13:535–43.[Abstract/Free Full Text]
  21. Scoote M, Poole-Wilson PA, Williams AJ. The therapeutic potential of new insights into myocardial excitation-contraction coupling. Heart 2003;89:371–6.[Abstract/Free Full Text]

Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?

Relevant Article

WEB TOP 10
Heart 2007 93: 791. [Extract] [Full Text] [PDF]

This article has been cited by other articles:

  • Fang, F., Chan, J. Y.-S., Yip, G. W.-K., Xie, J.-M., Zhang, Q., Fung, J. W.-H., Lam, Y.-Y., Yu, C.-M. (2009). Prevalence and determinants of left ventricular systolic dyssynchrony in patients with normal ejection fraction received right ventricular apical pacing: a real-time three-dimensional echocardiographic study. Eur J Echocardiogr 0: jep171v1-jep171 [Abstract] [Full Text]  
  • Sanderson, J. E. (2009). Echocardiography for cardiac resynchronization therapy selection: fatally flawed or misjudged?. J Am Coll Cardiol 53: 1960-1964 [Abstract] [Full Text]  
  • Kautzner, J., Peichl, P. (2008). Selecting CRT candidates: the value of intracardiac mapping. Europace 10: iii106-iii109 [Abstract] [Full Text]  
  • Chung, R, Sutton, R, Henein, M Y (2008). Beyond dyssynchrony in cardiac resynchronisation therapy. Heart 94: 991-994 [Abstract] [Full Text]  
  • Fung, J. W H, Yip, G. W K, Yu, C.-M. (2008). Does atrial fibrillation preclude biventricular pacing?. Heart 94: 826-827 [Full Text]  
  • Kimmel, M. W., Skadsberg, N. D., Byrd, C. L., Wright, D. J., Laske, T. G., Iaizzo, P. A. (2007). Single-site ventricular and biventricular pacing: investigation of latest depolarization strategy. Europace 9: 1163-1170 [Abstract] [Full Text]  

This Article

Services
Citing Articles
Google Scholar
PubMed
Topic Collections
Bookmark with

Register for free content

The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.