Article Text

Download PDFPDF

76 Are complications during pregnancy in women with mechanical heart valves influenced by their choice of anticoagulation?
Free
  1. Helen Parry1,
  2. Kate English2,
  3. James Oliver3,
  4. Damien Cullington2,
  5. Etienne Ciantar2,
  6. Nigel Simpson4,
  7. Sarah Winfield5,
  8. Derek Norfolk2
  1. 1Leeds Teaching Hospital
  2. 2Leeds Teaching Hospitals
  3. 3Leeds Teaching hospitals
  4. 4Leds Teaching hospitals
  5. 5Leeds teaching Hospitals

Abstract

Introduction Anticoagulation during pregnancy in women with mechanical valves is complex. Strategies include warfarin or low-molecular weight heparin (LMWH) throughout or LWMH during first trimester then warfarin until delivery. Warfarin poses risks of teratogenicity and fetal haemorrhage. However, LMWH poses increased thrombotic risk and frequent difficulties maintaining therapeutic peak and trough anti-Xa levels. We aimed to assess the complication rate in pregnant women with mechanical valves and whether anti-Xa levels were maintained within the recommended range with LMWH

Methods All pregnant women with mechanical valves under the ACHD team at Leeds General Infirmary were identified 2001- 2016. Medical records and blood results were analysed, identifying thrombotic and haemorrhagic complications, pregnancies leading to delivery of a healthy child and efficacy of anti-factor Xa monitoring.

Results The 12 patients identified had 25 pregnancies; 12 ultimately delivered a healthy child, 2 of which had no complications. Thrombotic events complicated 6 pregnancies, haemorrhage complicated 5 pregnancies and 1 pregnancy was complicated by both (including all pregnancies/miscarriages). Three pregnancies underwent planned termination, 7 miscarried pre-8 weeks gestation with 3 intra-uterine deaths. Ten patients used LMWH in the first trimester only and 5 used LMWH throughout pregnancy. The graph shows peak anti-factor Xa levels measured closest to complication development or average peak level if there were no complications (where measurements were available). The peak target was 1.0–1.2.

Conclusions Pregnancy in women with ACHD and mechanical valves carried significant risk of haemorrhage and thrombosis, regardless of anti-coagulation strategy. Anti-Xa levels were generally not maintained within target range.

Abstract 76 Figure 1

Graph shows patients rarely have anti factor xa levels in range.

  • Prosthetic valves
  • anticoagulation
  • pregnancy

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.