rss
Heart 82:62-67 doi:10.1136/hrt.82.1.62
  • Paper

Combined assessment of reflow and collateral blood flow by myocardial contrast echocardiography after acute reperfused myocardial infarction

Table 4

Diagnostic accuracy of dobutamine echocardiography and myocardial contrast echocardiography for prediction of improvement of contractile function at two month follow up

Sensitivity (%) Specificity (%) PPV (%) NPV (%)
Dobutamine echocardiography 60 90 86 69
Contrast reflow 75% 70 60 64 67
Contrast reflow 50% 100 30 58 100
Contrast collateral flow (+) 60 70 64 63
Contrast reflow 75% and/or collateral flow 100 60 69 100
Contrast reflow 75% and collateral flow 45 90 75 62
  • Reflow 75%, 75% of the risk area reperfused with contrast (“strong criterion”).

  • Reflow 50%, 50% of the risk area reperfused with contrast (“weak criterion”).

  • PPV, positive predictive value; NPV, negative predictive value.

This Article

Latest from Education in Heart

Latest from Education in Heart

Register for free content


Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of Heart.
View free sample issue >>

Free archive
The full back archive is now available for Heart. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.