Article Text

Download PDFPDF
Myocardial infarction during adenosine stress test
  1. J E Polad,
  2. L M Wilson
  1. Southampton General Hospital, Southampton, UK
  1. Correspondence to:
    Dr J Polad, Block 6, Southampton General Hospital, Southampton SO16 6YD, UK;
    jpolad{at}supanet.com

Abstract

A 65 year old woman with history of ischaemic heart disease underwent standard adenosine stress test for myocardial perfusion imaging. She sustained inferior myocardial infarction during the final stages of the stress test. She was admitted to the coronary care unit and received thrombolytic treatment. The patient made an uneventful recovery. Adenosine is widely used for myocardial stress imaging tests and has a good safety profile. So far there has been only one other reported myocardial infarction during adenosine stress test, which was under special circumstances because three days before the test the patient had undergone percutaneous transluminal coronary angioplasty when a severe circumferential dissection was noted. The present patient's case highlights the need to be aware of rare but potentially serious complications of adenosine, even though it generally has an excellent safety record for use in myocardial stress testing.

  • adenosine stress test
  • myocardial infarction

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes

Linked Articles