rss
Heart 89:1348-1349 doi:10.1136/heart.89.11.1348
  • Scientific letters

Symptomatic occlusion of the access vein after pacemaker or ICD lead extraction

Table 1

Incidence of symptomatic venous occlusion in patients with a patent access vein before extraction

n Symptomatic p Value
N %
ICD, implantable cardioverter-defibrillator; PM, pacemaker.
Extraction technique Traction 13 0 0 0.58
Laser 52 5 10
Indication Non-functional 28 4 14 0.15
Infection 37 1 3
PM/ICD ICD 14 2 14 0.29
PM 51 3 6
Total 65 5 8

This Article

Latest from Education in Heart

Latest from Education in Heart

Register for free content


Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of Heart.
View free sample issue >>

Free archive
The full back archive is now available for Heart. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.