rss
Heart 2005;91:1294-1298 doi:10.1136/hrt.2004.042549
  • Cardiovascular medicine

Effect of one or more co-morbid conditions on diagnostic accuracy of coronary flow velocity reserve for detecting significant left anterior descending coronary stenosis

  1. H Yoshitani1,
  2. M Takeuchi1,
  3. K Sakamoto1,
  4. T Akasaka2,
  5. K Yoshida2,
  6. J Yoshikawa3
  1. 1Department of Internal Medicine, Tane General Hospital, Osaka, Japan
  2. 2Department of Internal Medicine and Cardiology, Kawasaki Medical School, Kurashiki, Japan
  3. 3Department of Internal Medicine and Cardiology, Graduate School of Medicine, Osaka City University, Osaka, Japan
  1. Correspondence to:
    Dr Masaaki Takeuchi
    Department of Internal Medicine, Tane General Hospital, 1-2-31 Sakaigawa, Nishi-ku, Osaka 550-0024 Japan; masaaki_takeuchihotmail.com
  • Accepted 29 October 2004

Abstract

Objective: To determine the effect of one or multiple co-morbid conditions on the diagnostic accuracy of coronary flow velocity reserve (CFVR) in a heterogeneous patient population.

Methods: CFVR was measured in the left anterior descending coronary artery (LAD) by transthoracic Doppler echocardiography (TTDE) in 318 consecutive patients before elective coronary angiography. CFVR was calculated as the average peak diastolic velocity during intravenous ATP infusion divided by baseline flow velocity. All patients underwent coronary angiography within 48 hours. Significant LAD stenosis was defined as > 50% luminal narrowing. Diagnostic accuracy of CFVR was analysed according to the type and number of risk factors that may adversely affect microvascular function.

Results: CFVR was measured in 309 patients, of whom 105 were found to have significant LAD stenosis based on coronary angiography. CFVR < 2.0 had a sensitivity of 86% and a specificity of 77% for predicting significant LAD stenosis. Left ventricular hypertrophy (LVH) was the only factor that significantly lowered diagnostic accuracy (61% with LVH v 84% without LVH, p < 0.001). Diagnostic accuracy was not affected by increasing number of risk factors.

Conclusions: The diagnostic accuracy of CFVR by TTDE for detecting significant LAD stenosis remains high in a more clinically relevant population with multiple cardiovascular co-morbidities. Only the presence of LVH adversely affected diagnostic accuracy.

Footnotes

  • There was no financial support of this manuscript.

Latest from Education in Heart

Latest from Education in Heart

Register for free content


Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of Heart.
View free sample issue >>

Free archive
The full back archive is now available for Heart. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
Register to access the free archive >>

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.