Pericardial tamponade caused by transvenous temporary endocardial pacing

  1. M K Erol,
  2. S Sevimli,
  3. A Ates
  1. mkerolsuperonline.com

    A 65 year old man was admitted because of faintness and syncope. His ECG showed complete atrioventricular block with a heart rate of 30 beats/min. A transvenous temporary pacing electrode was inserted immediately via the right femoral vein. No complications were observed during the procedure. Coronary angiography was performed on the second day because of chest pain, and showed normal coronary arteries. The patient experienced severe chest pain and haemodynamic collapse two hours after coronary angiography. Transthoracic echocardiography demonstrated pericardial tamponade and the pacing electrode wire crossed the free right ventricular wall (panel). Surgical closure of the right ventricular free wall perforation and pericardial drainage was performed. A permanent pacemaker was later inserted without further complication.

    Heart perforation caused by a transvenous pacemaker is a rare complication.


    Graphic

    Register for free content


    Free sample
    This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of Heart.
    View free sample issue >>

    Free archive
    The full back archive is now available for Heart. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
    Register to access the free archive >>

    Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.