rss
Heart 2007;93:488-490 doi:10.1136/hrt.2006.087387
  • Original research

Troponin T measurement can predict persistent left ventricular dysfunction in peripartum cardiomyopathy

  1. C L Hu1,
  2. Y B Li2,
  3. Y G Zou3,
  4. J M Zhang4,
  5. J B Chen1,
  6. J Liu1,
  7. Y H Tang1,
  8. Q Z Tang1,
  9. C X Huang1
  1. 1Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, People’s Republic of China
  2. 2Department of Obstetrics and Gynecology, Renmin Hospital of Wuhan University, Wuhan, People’s Republic of China
  3. 3Department of Cardiology, Xiaogan General Hospital, Xiaogan, People’s Republic of China
  4. 4Department of Cardiology, Wuhan Xiehe Hospital, Wuhan, People’s Republic of China
  1. Correspondence to:
    Dr C L Hu
    Department of Cardiology, Renmin Hospital, Wuhan University School of Medicine, 238 JieFang Road, Wuchang District, Wuhan 430060, People’s Republic of China; chenglinhu{at}yahoo.com
  • Accepted 15 August 2006
  • Published Online First 25 October 2006

Abstract

Objective: To determine whether measurement of cardiac troponin T (cTnT) concentration in newly diagnosed peripartum cardiomyopathy (PPCM) can be used to predict persistent left ventricular dysfunction after a 6-month follow-up.

Patients and methods: This was a prospective, multiple-centre clinical trial that studied 106 patients with newly diagnosed PPCM surviving over 6 months. cTnT concentration was measured within 2 weeks of the onset of PPCM.

Results: Serum cTnT concentration was negatively correlated with left ventricular ejection fraction (LVEF) at follow-up (LVEF, r = −0.518, p = 0.0001). Analysis by receiver operator characteristic curve yielded an area under the curve of 0.764 (95% CI 0.669 to 0.860, p = 0.0001, vs null hypothesis value 0.5) for cTnT, and a cTnT concentration cut off of >0.04 ng/ml, predicting persistent left ventricular dysfunction with a sensitivity of 54.9% and a specificity of 90.9%. Among 106 recruited patients, there were 33 patients with cTnT concentrations >0.04 ng/ml and 73 patients with cTnT concentrations ≤0.04 ng/ml. After a 6-month follow-up, there was significantly smaller LVEF (35.42% (13.04% vs 50.16% (10.48%, p = 0.0001) and more persistent left ventricular dysfunction (84.8% vs 31.5%, OR = 12.17 (95% CI 4.17 to 35.57), p = 0.001) in patients with cTnT >0.04 ng/ml than in patients with cTnT ≤0.04 ng/ml.

Conclusion: Serum cTnT concentration measured within 2 weeks of the onset of PPCM was correlated negatively with LVEF at follow-up. This marker offers a simple, quick, inexpensive, non-invasive method for predicting a persistent LVEF of ≤50%. A cTnT concentration of >0.04 ng/ml predicted persistent left ventricular dysfunction with a sensitivity of 54.9% and a specificity of 90.9%.

Footnotes

  • Published Online First 25 October 2006

  • Competing interests: None.

This Article

  1. All Versions of this Article:
    1. hrt.2006.087387v1
    2. 93/4/488 most recent

Services

  1. Request permissions

Responses

  1. Submit a response
  2. No responses published

Social bookmarking

Latest from Education in Heart

Latest from Education in Heart

Register for free content


Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of Heart.
View free sample issue >>

Free archive
The full back archive is now available for Heart. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
Register to access the free archive >>

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.