rss
Heart 94:1627-1633 doi:10.1136/hrt.2007.135475
  • Original article
  • Valvular heart disease

Myocardial blood flow in patients with low-flow, low-gradient aortic stenosis: differences between true and pseudo-severe aortic stenosis. Results from the multicentre TOPAS (Truly or Pseudo-Severe Aortic Stenosis) study

  1. I G Burwash1,
  2. M Lortie1,
  3. P Pibarot2,
  4. R A de Kemp1,
  5. S Graf3,
  6. G Mundigler3,
  7. A Khorsand3,
  8. C Blais2,
  9. H Baumgartner3,
  10. J G Dumesnil2,
  11. Z Hachicha2,
  12. J DaSilva1,
  13. R S B Beanlands1
  1. 1
    Division of Cardiology, University of Ottawa Heart Institute, Ottawa, Ontario, Canada
  2. 2
    Quebec Heart Institute, Laval University, Sainte-Foy, Quebec, Canada
  3. 3
    Medical University of Vienna, Vienna, Austria
  1. Dr I G Burwash, University of Ottawa Heart Institute, 40 Ruskin Street, Ottawa, Ontario, Canada K1Y 4W7; iburwash{at}ottawaheart.ca
  • Accepted 27 February 2008
  • Published Online First 1 April 2008

Abstract

Background: Impairment of myocardial flow reserve (MFR) in aortic stenosis (AS) with normal left ventricular function relates to the haemodynamic severity.

Objectives: To investigate whether myocardial blood flow (MBF) and MFR differ in low-flow, low-gradient AS depending on whether there is underlying true-severe AS (TSAS) or pseudo-severe AS (PSAS).

Methods: In 36 patients with low-flow, low-gradient AS, dynamic [13N]ammonia PET perfusion imaging was performed at rest (n = 36) and during dipyridamole stress (n = 20) to quantify MBF and MFR. Dobutamine echocardiography was used to classify patients as TSAS (n = 18) or PSAS (n = 18) based on the indexed projected effective orifice area (EOA) at a normal flow rate of 250 ml/s (EOAIproj ⩽ or >0.55 cm2/m2).

Results: Compared with healthy controls (n = 14), patients with low-flow, low-gradient AS had higher resting mean (SD) MBF (0.83 (0.21) vs 0.69 (0.09) ml/min/g, p = 0.001), reduced hyperaemic MBF (1.16 (0.31) vs 2.71 (0.50) ml/min/g, p<0.001) and impaired MFR (1.44 (0.44) vs 4.00 (0.91), p<0.001). Resting MBF and MFR correlated with indices of AS severity in low-flow, low-gradient AS with the strongest relationship observed for EOAIproj (rs = −0.50, p = 0.002 and rs = 0.61, p = 0.004, respectively). Compared with PSAS, TSAS had a trend to a higher resting MBF (0.90 (0.19) vs 0.77 (0.21) ml/min/g, p = 0.06), similar hyperaemic MBF (1.16 (0.31) vs 1.17 (0.32) ml/min/g, p = NS), but a significantly smaller MFR (1.19 (0.26) vs 1.76 (0.41), p = 0.003). An MFR <1.8 had an accuracy of 85% for distinguishing TSAS from PSAS.

Conclusions: Low-flow, low-gradient AS is characterised by higher resting MBF and reduced MFR that relates to the AS severity. The degree of MFR impairment differs between TSAS and PSAS and may be of value for distinguishing these entities.

Footnotes

  • Funding: Supported by grants from the Canadian Institutes of Health Research (MOP 57745), Ottawa, Canada.

  • Competing interests: None declared.

  • Ethics approval: Approved by the local research ethics committees.

Relevant Article

Latest from Education in Heart

Latest from Education in Heart

Register for free content


Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of Heart.
View free sample issue >>

Free archive
The full back archive is now available for Heart. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
Register to access the free archive >>

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.