rss
Heart 95:1153-1158 doi:10.1136/hrt.2008.162677
  • Original article
  • Heart rhythm disorders and pacemakers

Troponin T elevation after implanted defibrillator discharge predicts survival

  1. D Blendea1,
  2. M Blendea2,
  3. J Banker1,
  4. C A McPherson1
  1. 1
    Cardiac Electrophysiology Service, Department of Medicine, Bridgeport Hospital, Yale University School of Medicine, Bridgeport, Connecticut, USA
  2. 2
    Department of Medicine, University of Massachusetts Medical School, Worcester, Massachusetts, USA
  1. Dr D Blendea, Cardiac Electrophysiology Service, Department of Medicine, Bridgeport Hospital, Yale University School of Medicine, 267 Grant St, Bridgeport, CT 06610, USA; dblendea{at}me.com
  • Accepted 17 March 2009
  • Published Online First 13 April 2009

Abstract

Background: Cardiac troponin T (cTnT) elevations have been reported to occur after implantable cardioverter-defibrillator (ICD) discharges, but their prognostic significance is unknown.

Objective: To evaluate whether cTnT elevations occurring after ICD discharges have an impact on survival.

Design: Prospective observational study.

Patients: 174 patients (mean (SD) age 68 (12) years, 32 women) who received spontaneous (n = 66) or induced (n = 108) ICD discharges were studied. The mean (SD) left ventricular ejection fraction was 29 (11)%.

Main outcome measures: Troponin T was measured between 12 and 24 h after ICD discharge. Patients received between 1 and 19 discharges (mean (SD) 2.4 (2.4)), with total delivered energy ranging from 6 to 288 J (mean (SD) 41 (63) J). The relationship between cTnT levels and all-cause mortality was assessed in univariate and multivariate analyses.

Results: During a median follow-up period of 41.8 months (range 3–123), 56 patients died. Patients with a post-discharge cTnT level of ⩾0.05 ng/ml had worse survival than those with cTnT <0.05 ng/ml. The significant relationship between raised cTnT and survival was retained in Cox multivariate analysis adjusted for total ICD energy delivered during an arrhythmia episode, age, sex, presence of coronary artery disease, left ventricular ejection fraction and serum creatinine.

Conclusions: Elevation of troponin T after ICD discharge, even when it occurs after device testing, is a risk factor for mortality that is independent of other common clinical factors that predict survival in such patients.

Footnotes

  • Competing interests: None.

  • Ethics approval: Ethics committee approval obtained from Bridgeport Hospital Internal Review Board.

Latest from Education in Heart

Latest from Education in Heart

Register for free content


Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of Heart.
View free sample issue >>

Free archive
The full back archive is now available for Heart. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
Register to access the free archive >>

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.