Absolute myocardial blood flow determination using real-time myocardial contrast echocardiography during adenosine stress: comparison with single-photon emission computed tomography

  1. S S Abdelmoneim1,
  2. A Dhoble1,
  3. M Bernier1,
  4. S Moir1,
  5. M E Hagen1,
  6. S A C Ness1,
  7. S S Abdel-Kader2,
  8. P A Pellikka1,
  9. S L Mulvagh1
  1. 1
    Division of Cardiovascular Diseases, Mayo Clinic, Rochester, Minnesota, USA
  2. 2
    Department of Cardiovascular Medicine, Assiut University, Assiut, Egypt
  1. Correspondence to Dr Sharon L Mulvagh, Division of Cardiovascular Diseases, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA; smulvagh{at}mayo.edu
  • Accepted 11 June 2009
  • Published Online First 6 July 2009

Abstract

Objective: To assess the feasibility and diagnostic accuracy of real-time myocardial contrast echocardiography (MCE)-derived absolute myocardial blood flow for detection of myocardial perfusion abnormalities compared with simultaneous technetium 99 m sestamibi single-photon emission computed tomography (SPECT).

Design: Prospective study.

Setting: Tertiary-care medical institution.

Patients: 79 patients with known or suspected coronary artery disease.

Interventions: Simultaneous SPECT and real-time MCE during adenosine stress.

Main outcome measures: Absolute myocardial blood flow (MBF, ml/min/g), microbubble velocity (β, min−1), and reserve values. Endpoints included sensitivity, specificity, positive likelihood ratio (LR+) or negative likelihood ratio (LR−) and area under the curve (AUC) of the receiver operating characteristic curve.

Results: Reserve measurements were feasible in 975 of 1343 segments (73%); of these, 130 segments (13%) were abnormal by SPECT. MCE perfusion parameters clearly distinguished abnormal from normal segments for β reserve (1.13 (0.99) vs 2.22 (1.36), p<0.001) and MBF reserve (1.80 (2.29) vs 3.69 (2.79), p<0.001). The β reserve cut-off of 1.60 provided the following: AUC, 0.787; sensitivity, 82%; specificity, 66%; LR+, 2.40; and LR−, 0.28. The MBF reserve cut-off of 1.90 provided the following: AUC, 0.779; sensitivity, 73%; specificity, 72%; LR+, 2.69; and LR−, 0.37. MBF reserve had an AUC of 0.773 for the left anterior descending coronary artery, 0.885 for the left circumflex coronary artery and 0.739 for the right coronary artery.

Conclusions: Real-time MCE-derived absolute MBF, β, and reserve values are feasible and accurate for detecting myocardial perfusion abnormalities as defined by SPECT.

Footnotes

  • Competing interests SLM received a research grant from Lantheus Medical Imaging and Astellas Pharma. There are no conflicts of interest to disclose for the remaining authors.

  • Provenance and Peer review Not commissioned; externally peer reviewed.

This Article

  1. All Versions of this Article:
    1. hrt.2009.169268v1
    2. 95/20/1662 most recent

Services

  1. Request permissions

Responses

  1. Submit a response
  2. No responses published

Social bookmarking

Latest from Education in Heart

Latest from Education in Heart

Register for free content


Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of Heart.
View free sample issue >>

Free archive
The full back archive is now available for Heart. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
Register to access the free archive >>

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.