rss
Heart 2010;96:220-225 doi:10.1136/hrt.2009.168112
  • Cardiac imaging and non-invasive testing

Real-time perfusion echocardiography during treadmill exercise and dobutamine stress testing

  1. S Dodla,
  2. F Xie,
  3. M Smith,
  4. E O'Leary,
  5. T R Porter
  1. Department of Internal Medicine, Section of Cardiology, University of Nebraska Medical Center, Omaha, Nebraska, USA
  1. Correspondence to Dr Thomas R Porter, University of Nebraska Medical Center, 982265 Nebraska Medical Center, Omaha, NE 68198-2265, USA; trporter{at}unmc.edu
  • Accepted 11 August 2009
  • Published Online First 26 August 2009

Abstract

Background Real-time perfusion (RTP) echocardiographic imaging with a continuous infusion of microbubbles has improved the sensitivity of dobutamine stress echocardiography (DSE) in detecting coronary artery disease (CAD). The impact of RTP on treadmill exercise stress echocardiography (TESE) is unclear.

Design Retrospective database review.

Setting/patients/interventions RTP was utilised in 254 DSE and TESE patients being examined for the presence of significant CAD. A continuous infusion of 3% Definity (Lantheus Medical Imaging) was used for all studies, and contrast replenishment (MCR), plateau intensity (PMCE) and wall motion (WM) were examined for the detection of CAD.

Main outcome measures Sensitivity/specificity/accuracy to detect CAD.

Results For DSE, the sensitivity of myocardial perfusion (MP) imaging with RTP was 85%, which was significantly higher than WM analysis (72%; p<0.05). The improvement in sensitivity with MP analysis during DSE was primarily the result of better detection of left anterior descending disease. MP sensitivity during TESE was significantly better than MP sensitivity during DSE (98% versus 85%; p<0.05), and WM sensitivity during TESE was better than WM sensitivity during DSE (89% versus 72%; p<0.05). The improvement in WM sensitivity during TESE was due to detection of subendocardial wall thickening abnormalities in 48% of the patients with induced subendocardial perfusion defects.

Conclusion Myocardial perfusion imaging with RTP improves the detection of CAD during both DSE and TESE. During TESE, the subendocardial perfusion defects improve WM sensitivity by delineating subendocardial WM abnormalities.

Footnotes

  • Funding Theodore Hubbard Foundation, Omaha, NE, Lantheus Medical Imaging.

  • Competing interests None.

  • Provenance and peer review Not commissioned; externally peer reviewed.

Latest from Education in Heart

Latest from Education in Heart

Register for free content


Free sample
This recent issue is free to all users to allow everyone the opportunity to see the full scope and typical content of Heart.
View free sample issue >>

Free archive
The full back archive is now available for Heart. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006, back to volume 1 issue 1.
Register to access the free archive >>

Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.