Article Text

PDF

GW23-e2495
PULMONARY VEIN ISOLATION FOR ATRIAL FIBRILLATION USING A NOVEL MULTIELECTRODE CATHETER: A FEASIBILITY AND EFFICACY STUDY
  1. Xiao-Ming Chen1,
  2. Sotiris Nedios2,
  3. Mattias Roser2,
  4. Charalampos Kriatselis2,
  5. Min Tang3,
  6. Eckard Fleck2,
  7. Jin-Hong Gerds-Li2
  1. 1First Affiliated Hospital of Jinan University
  2. 2German Heart Institute Berlin, Berlin, Germany
  3. 3Fuwai Hospital & Cardiovasc Institute, Chinese Academy of Medical Science, Peking Union of Medical College

    Abstract

    Objectives To evaluate the feasibility and safety of a novel multi-electrode pulmonary vein ablation catheter (PVAC) combining circular mapping and duty-cycled multi-electrode radiofrequency (RF) energy delivery, and guided by three-dimensional rotational angiography (3D-RTA) for atrial fibrillation (AF).

    Methods 47 patients (aged 62±11 years) with symptomatic AF 32 cases for paroxysmal AF and 15 cases for persistent AF were enrolled to undergo pulmonary vein isolation (PVI) with PVAC guided by 3D-RTA.

    Results Mean total procedural time was 126.4±29.5 min (123.7±15.7 min for the paroxysmal AF patients and 132.0±36.6 min for the persistent AF patients, p>0.05); mean fluoroscopy time was 30.3±11.3 min (29.4±9.8 min for the paroxysmal AF patients and 32.3±14.2 min for the persistent AF patients, p>0.05); mean PVAC ablation time was 21.6±7.7 min (20.5±6.0 min for the paroxysmal AF patients and 24.0±10.4 min for the persistent AF patients, p>0.05). A total of 172 PVs (172/183, 94.0%) were completely isolated. Two cases of mild pericardial effusion were detected on the first postprocedural day and absorbed in a week. No incidence of PV stenosis was observed during the follow-up. At follow-up (mean 8±5 months, range 3–22 months), 32 (68.1%) patients reported significantly improved symptoms or were entirely asymptomatic. 29 of 47 (61.7%) patients were free from AF.

    Conclusions The novel technology of the PVAC catheter using duty-cycled bipolar and unipolar RF energy and guided by 3D-RTA suggests a feasible, safe, and promising alternative to conventional point-by-point ablation.

    Statistics from Altmetric.com

    Request permissions

    If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.