CLINICAL APPLIED RESEARCH OF PERCUTANEOUS BALLOON PULMONARY VALVE FOR CONGENITAL PULMONARY VALVE STENOSIS
Free
  1. Xie Dongming1,
  2. xie dongyang1,
  3. yan yihong1,
  4. Xie Dongming2
  1. 1Affiliated Hospital of Gannan Medical College
  2. 2Affiliated Hospital of Gannan Medical College

    Abstract

    Objectives To evaluate the clinical efficacy of percutaneous balloon pulmonary valvuloplasty (PBPV) for pulmonary valve stenosis (PS)

    Methods 20 patients, through clinical, ECG, chest X-ray and cardiac ultrasound, were diagnosis as pure PS. Before PBPV, determination PS's type and valve annulus size, to select balloon diameter larger than its about 20–40%. After balloon expansion instantly measured pulmonary pressure gradient, and observed the pulmonary valve open, ejection, pressure gradient, tricuspid and pulmonary valve regurgitation after PBPV.

    Results All 20 patients were successful with the balloon dilation, pressure gradient decreased 63.65% (p<0.01), 1 patients had mild pulmonary valve regurgitation, and 1 case in intraoperative occurred sinus bradycardia and disappeared by using atropine, no any serious complications.

    Conclusions PBPV treatment for pulmonary valve stenosis with a high success rate, little trauma and few complications, and could be the first choice for PS treatment.