Table 3

Results of quantitative coronary angiography

Overall (n=67)In-stent restenosis (n=46)De novo/restenosis (n=21)p Value
Data are mean (SD).
Lesion length (mm)23.56 (20.38)26.13 (22.93)17.94 (11.77)0.058
Pre-intervention
    Reference lumen diameter (mm)4.19 (0.52)4.22 (0.52)4.15 (0.54)0.626
    Minimum lumen diameter (mm)0.73 (0.62)0.75 (0.61)0.69 (0.67)0.738
    Diameter stenosis (%)82 (15)82 (15)84 (15)0.617
Postintervention
    Reference lumen diameter (mm)4.21 (0.53)4.23 (0.53)4.15 (0.54)0.560
    Minimum lumen diameter (mm)3.77 (0.69)3.64 (0.68)4.05 (0.65)0.023
    Diameter stenosis (%)11 (11)14 (11)3 (7)<0.001
At follow up
    Reference lumen diameter (mm)4.20 (0.53)4.23 (0.55)4.13 (0.51)0.510
    Minimum lumen diameter (mm)2.94 (1.50)2.69 (1.42)3.53 (1.56)0.049
    Diameter stenosis (%)31 (34)37 (32)18 (34)0.047
    Binary restenosis (%)18.621.411.80.388
Change in minimum lumen diameter
    Acute gain (mm)3.02 (0.88)2.87 (0.90)3.35 (0.77)0.038
    Late loss (mm)0.86 (1.25)1.02 (1.27)0.48 (1.14)0.128
    Net gain (mm)2.15 (1.54)1.95 (1.55)2.64 (1.45)0.094