Table 3

 Pooled incidence of valve related events and their outcomes after aortic valve replacement with a mechanical valve and a bioprosthesis

Valve related eventsEvents (n)LOR (per 100 patient-years)Outcome, death rateReoperation rate
MechBioMechBioMechBioMechBio
*A Gompertz model was constructed.
†A two period exponential model was constructed for risk during and after the first six months after implantation.
‡A Weibull model was constructed incorporating age dependency.
Bio, bioprosthesis; LOR, linearised occurrence rate (or hazard); Mech, mechanical valve; NSD, non-structural dysfunction; SVD, structural valvar deterioration.
Valve thrombosis3920.160.010.220.670.630.33
Thromboembolism4197171.61.30.170.1800.01
Haemorrhage4191891.6*0.40.140.200
Endocarditis892403.9/0.66†3.2/0.48†0.430.360.530.5
NSD70910.290.30.0400.370.43
SVD0469000.1200.75