Table 1

 Clinical and angiographic features at initial stenting and during stent thrombosis

PatientAge (years)SexVessel/ symptoms*QCA before stentingQCA after stentingTime (stent to occlusion) (h)Time (pain to angiography) (min)Stent occlusion presentation†FindingsFinal QCAOutcome
MLD (mm)%DSMLD (mm)%DSMLD (mm)%DS
%DS, percentage diameter stenosis; Ds, dissection; F, female; IFD, intraluminal filling defect; LAD, left anterior descending coronary artery; LCX, left circumflex coronary artery; M, male; MI, myocardial infarction; MLD, minimum lumen diameter; NA, not available; NQWMI, non-Q wave myocardial infarction; QCA, quantitative coronary angiography; QWMI, Q wave myocardial infarction; RCA, right coronary artery; STSE, ST segment elevation on ECG; TIMI, thrombolysis in myocardial infarction; UA, unstable angina; VF, ventricular fibrillation.
*Clinical symptoms at initial stenting; †clinical presentation of stent thrombosis; ‡only troponin increase; §angiographic underexpansion of the stent was accepted after the procedure to avoid losing a major diagonal branch.
139MLAD/UA0.682%1.912%0.515UAIFD, TIMI 22.112%Uneventful
250MLAD/MI1.062%2.618%2360STSETIMI 04.27%Uneventful
368FLAD/MINANANANA160VF, STSETIMI 02.011%NQWMI
468MLAD/UA0.677%2.031%145STSEIFD, TIMI 12.110%QWMI
556MLAD/MI0.955%1.810%0.3105STSETIMI 02.413%NQWMI
668MLCX/UA1.253%2.312%190STSETIMI 02.315%QWMI
735MLAD/MI0.672%2.315%96120STSETIMI 02.614%NQWMI
851FRCA/UA0.863%2.06.0%120120STSETIMI 0, Ds2.120%QWMI
954MLAD/UA0.963%2.214%672130STSETIMI 02.411%QWMI
1064MLAD/MI0100%1.826%96180STSETIMI 02.312%NQWMI
1163MRCA/MI0100%2.821%456360STSEIFD, TIMI 23.09%NQWMI‡
1264MLAD/MI1.349%1.835%§2030STSETIMI 02.613%NQWMI‡