Table 4

 Diagnostic performance of dobutamine SPECT MPI

AuthorNumber of patientsTracerAnalysisMI excludedQualitySensitivitySpecificity
*Values were calculated for patients with and without myocardial infarction, values shown include those with myocardial infarction; †coronary stenosis ⩾70%.
Sensitivity and specificity values for coronary stenosis ⩾50% and coronary stenosis ⩾70%. Quality is rated according to the number of quality criteria (adequate description of study group, avoidance of verification bias, avoidance of diagnostic and test review bias) met.
MI, myocardial infarction; mibi, technetium-99m sestamibi; Q, quantitative analysis; tetro, technetium-99m tetrofosmin; Tl-201, thallium-201; uns, unspecified; V, visual analysis.
Pennell 19914750Tl-201VnoMedium97%80%
Warner 19934816Tl-201VnoMedium93%100%
Hays 19934967Tl-201QnoMedium86%90%
Huang 19975093Tl-201QnoHigh90%81%
Huang 199851110Tl-201VyesHigh82%82%
Caner 19975229Tl-201; mibiVunsHigh89%70%
Gunalp 19935327mibiVyesMedium94%89%
Forster 19935421mibiVyesHigh83%89%
Marwick 19934597mibiVyesMedium80%74%
Marwick 199355217mibiQyesHigh76%67%
Mairesse 199456129mibiVyesHigh76%65%
Marwick 19941982mibiVyesMedium65%68%
Senior 19945761mibiVnoHigh95%71%
Di Bello 19965845mibiVyesHigh87%86%
Iftihar 19965938mibiVnoMedium79%90%
Kisacik 19966069mibiVnoHigh96%64%
Slavich 19966146mibiVyesMedium82%83%
San Roman 19986292mibiQyesHigh87%70%
†Santoro 19986360mibiQyesHigh91%81%
Elhendy 19986470mibiVnoLow64%72%