Table 2

 DSE data for patients with and without angina during DSE

Silent ischaemia (n = 643)Symptomatic ischaemia (n = 288)p Value
Data are mean (SD) or number (%).
Peak heart rate (beats/min)127 (21)124 (20)0.03
Peak systolic blood pressure (mm Hg)135 (31)134 (28)0.7
Peak rate pressure product16 573 (4290)17 119 (4767)0.1
Peak dobutamine dose (μg)37 (7)38 (5)0.09
Atropine use230 (36%)96 (33%)0.5
ST segment depression248 (38%)179 (62%)<0.001
Number of dysfunctional segments at rest9.6 (5.1)8.8 (5.0)0.1
Number of ischaemic segments3.5 (2.2)3.8 (2.1)0.2
Arrhythmias and hypotension during the test43 (7%)12 (4%)0.2
Reasons for termination of the stress test
    85% of maximum heart rate579 (90%)250 (87%)0.2
    Maximum dose36 (5%)14 (5%)0.8
    Arrhythmias12 (2%)2 (1%)0.3
    Side effects11 (2%)1 (0.3%)0.2
    ST segment depression5 (1%)10 (3%)<0.005
    Angina0 (0%)11 (4%)<0.0001