Abstract 025 Table
Stenosed N  =  59Remote N  =  73Nornal N  =  60p Value
Rest MBF corrected (ml/min/g/ (mm Hg.bpm/104))1.43 ± 0.05 (1.34 to 1.52)1.42 ± 0.04 (1.34 to 1.51)1.39 ± 0.04 (1.31 to 1.46)0.76
Hyperaemic MBF (ml/min/g)2.11 (1.66 to 2.42)*‡2.73 (2.16 to 3.44)†3.69 (3.16 to 4.61)<0.001
BOLD SI change (%)1.25 (−2.38 to 7.89)*‡8.91 (4.95 to 12.78)†14.08 (9.23 to 22.20)<0.001
  • Data are presented as means ± SD (95% CI) or median (interquartile range) as appropriate. *p<0.05 for comparison between stenosed and remote segments; †p<0.05 for comparison between remote to ischemia and normal segments; ‡p<0.05 for comparison between stenosed and normal segments. BOLD, blood oxygen level-dependent; MBF, myocardial blood flow; SI, signal intensity.