Table 2

Diagnostic values of exercise electrocardiography, inotropic stress echocardiography, and MIBI imaging for detecting multivessel disease

Total study group (n = 100)Excluding previous MI (n = 71)
Sens (%)Spec (%)Accuracy
(%)
Sens
(%)
Spec
(%)
Accuracy
(%)
Exercise ECG7041572-150 6138482-150
MIBI6873 706682 75
Echo6882 746385 75
MIBI + echo82 617378 6973
  • Accuracy, diagnostic accuracy; sens, sensitivity; spec, specificity.

  • 2-150 p < 0.01 v MIBI, echo, and MIBI + echo; p < 0.01v exercise ECG; p < 0.01 v MIBI and echo alone.