Patient | Time from TCPC to occlusion (months) | Coil (⊘ mm/loops) | SaO2 (%) pre | SaO2 (%) post | RAP pre (mm Hg) | RAP post (mm Hg) | Type of interatrial communication | Result of coil closure (angiography) | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | 39 | 1×3/4 | 86 | 92 | 8 | 9 | Residual leak after Rashkind umbrella occlusion of fenestration, interatrial venous communication | Complete | ||||||||
3×5/5 | ||||||||||||||||
2 | 15 | 1×5/5 | 87 | 92 | 11 | 11 | Interatrial venous communication | Complete | ||||||||
1×3/4 | ||||||||||||||||
3 | 12 | 1×5/4 | 89 | 92 | 11 | 12 | Spontaneous closure of fenestration, interatrial venous communication | Complete | ||||||||
4 | 15 | 1×5/5 | 87 | 91 | 6 | 6 | Residual leak at fenestration | Partial | ||||||||
5 | 60 | 4×5/4 | 87 | 89 | 10 | 11 | Multiple defects at suture line | Complete2-150 | ||||||||
6 | 12 | 1×5/4 | 88 | 92 | 11 | 12 | Residual defect at suture line | Partial | ||||||||
7 | 58 | 1×5/4 | 89 | 93 | 11 | 13 | Residual leak at fenestration | Complete |
↵2-150 Additional intrapulmonary fistula.
TCPC, total cavopulmonary connection; ⊘ diameter of coil; SaO2, aortic oxygen saturation; pre, preocclusion; post, postocclusion; RAP, right atrial pressure.