Table 2

Comparison of the accuracy between fundamental and second harmonic imaging during dobutamine stress echocardiography for the detection of myocardial viability

Variable Fundamental imaging
(n (%))
95% CI Second harmonic imaging
(n (%))
95% CI p Value
Sensitivity for dysfunctional segments2-150 73% (144/198)68 to 7887% (138/158)83 to 910.001
Specificity for dysfunctional segments2-150 86% (113/132)82 to 8990% (117/130)86 to 940.40
Accuracy for dysfunctional segments2-150 78% (257/330)73 to 8289% (255/288)85 to 920.001
Sensitivity for akinetic/dyskinetic segments2-160 75% (60/80)68 to 8290% (54/60)85 to 950.06
Specificity for akinetic/dyskinetic segments2-160 84% (85/101)78 to 9084% (78/93)78 to 900.90
Accuracy for akinetic/dyskinetic segments2-160 80% (145/181)74 to 8686% (132/153)81 to 920.20
  • 2-150 Wall motion score > 2;

  • 2-160 wall motion score > 3.

  • CI, confidence interval.