Table 3

Accuracy of low dose dobutamine echocardiography (LDDE) and 201thallium SPECT in predicting functional recovery after revascularisation of akinetic segments in patients with a non-occluded (group 1) and an occluded (group 2) left anterior descending coronary artery

LDDE201Thallium SPECT
Group 1Group 2Group 1Group 2
Sensitivity72% (13/18)26% (9/34)3-165 67% (10/15)79% (19/24)3-170
Specificity94% (46/49)93% (52/56)26% (5/19)3-170 60% (9/15)3-164
Accuracy88% (59/67)68% (61/90)3-160 44% (15/34)3-151 72% (28/39)3-150
PPV81% (13/16)69% (9/13)42% (10/24)3-151 76% (19/25)3-150
NPV90% (46/51)67% (52/77)3-160 50% (5/10)3-151 64% (9/14)
  • 3-150 p < 0.05;

  • 3-160 p < 0.01;

  • 3-165 p < 0.001v group 1.

  • 3-151 p > 0.05;

  • 3-164 p < 0.01;

  • 3-170 p < 0.001v LDDE.

  • NPV, negative predictive value; PPV, positive predictive value; SPECT, single photon emission computed tomography.