Skip to main content
Log in

Quantitative evaluation of myocardial single-photon emission tomographic imaging: application to the measurement of perfusion defect size and severity

  • Original Article
  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

A new method is described for precise quantitative analysis of the relative three-dimensional distribution of myocardial tracers. The system uses a 360° elliptical sampling of radial slices to create activity profiles. These are then positioned onto a common centre at the same angular coordinates as the corresponding radial slice reconstruction planes to generate a two-dimensional polar summary display. Abnormal distribution is then identified by automatic comparison of the patient polar map with the threshold of a normal database defined on a pixel by pixel basis as the normal mean −2.5 SD. Our stress and rest databases currently comprise 34 and 24 studies for sestamibi and tetrofosmin respectively. The present method differs from currently available software in two major respects. First, radial slices are used rather than short-axis slices to minimize operator intervention and to allow quantitative evaluation of the left ventricle volume independent of the heart size and without truncation, in particular near the apex and at the base. This sampling scheme also results in a more homogeneous and sampling-independent partial volume effect. Secondly, quantitative analysis is improved by calculating perfusion defect severity, extent and size in a precise manner. Severity is evaluated relative to a standardized background measurement and to the mean normal value rather than to the threshold value. This parameter was underestimated up to a defect extent of 32 cm2 in our phantom studies. Calculation of defect extent takes into account the surface distortion resulting from planar projection by using pixel by pixel weighted factors but it is otherwise overestimated as a result of the limited resolution of the imaging system. Integrating defect severity and extent, our hypoperfusion index appeared to accurately estimate the true defect size in our phantom model (r=0.993). The reproducibility of analysis was 6.24% in phantom studies and 3.10% in patient studies including repeated acquisitions. Applied to a well-documented population of 80 patients, this method resulted in an 86% sensitivity and a 78% specificity for overall coronary artery disease detection with reference to the angiographic data.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Fintel DJ, Links JM, Brinker JA, et al. Improved diagnostic performance of exercise thallium-201 single photon emission computed tomography over planar imaging in the diagnosis of coronary artery disease: a receiver operating characteristic analysis.J Am Coll Cardiol 1989; 13: 600–612.

    Google Scholar 

  2. Kiat H, Maddahi J, Roy LT, et al. Comparison of technetium 99m methoxy isobutyl isonitrile and thallium 201 for evaluation of coronary artery disease by planar and tomographic methods.Am Heart J 1989; 117: 1–11.

    Google Scholar 

  3. Blokland JAK, Reiber HHC, Pauwels EKJ. Quantitative analysis in single photon emission tomography (SPET).Eur J Nucl Med 1992; 19: 47–61.

    Google Scholar 

  4. Garcia EV, Van Train K, Maddahi J, et al. Quantification of rotational thallium-201 myocardial tomography.J Nucl Med 1985; 26: 17–26

    Google Scholar 

  5. Germano G, Van Train KF, Garcia EV, et al. Quantitation of myocardial perfusion with SPELT: current issues and future trends. In: Zaret BL, Beller GA, eds.Nuclear Cardiology, St. Louis: Mosby; 1993: 77–88.

    Google Scholar 

  6. Van Train KF, Garcia EV, Cooke D, Areeda J. Quantitative analysis of SPELT myocardial perfusion. In: DePuey EG, Berman DS, Garcia EV, eds.Cardiac SPELT imaging. New York: Raven Press; 1995: 49–74.

    Google Scholar 

  7. Maddahi J, Kiat H, Van Train KF, et al. Myocardial perfusion imaging with technetium-99m sestamibi SPELT in the evaluation of coronary artery disease.Am J Cardiol 1990; 66: 55E-62E.

    Google Scholar 

  8. Maddahi J, Van Train K, Prigent F, et al. Quantitative single photon emission computed thallium-201 tomography for detection and localization of coronary artery disease: optimization and prospective validation of a new technique.J. Am Coll Cardiol 1989; 14: 1689–1699.

    Google Scholar 

  9. Van Train KF, Areeda J, Garcia EV, et al. Quantitative sameday rest-stress technetium-99m-sestamibi SPELT: definition and validation of stress normal limits and criteria for abnormality.J Nucl Med 1993; 34: 1494–1502.

    Google Scholar 

  10. Burow RD, Pond M, Schafer AW, Becker L. “Circumferential profiles”: a new method for computer analysis of thallium-201 myocardial perfusion images.J Nucl Med 1979; 20: 771–777.

    Google Scholar 

  11. Wackers FJT, Fetterman RC, Mattera JA, Clements JP. Quantitative planar thallium-201 stress scintigraphy: a critical evaluation of the method.Semin Nucl Med 1985; 15: 46–66.

    Google Scholar 

  12. Ritchie JL, Williams DL, Caldwell JH, et al. Seven-pinhole emission tomography with thallium-201 in patients with prior myocardial infarction.J Nucl Med 1981; 22: 107–112

    Google Scholar 

  13. Caldwell JH, Williams DL, Harp GD, et al. Quantitation of size of relative myocardial perfusion defect by single-photon emission computed tomography.Circulation 1984; 70: 1048–1056.

    Google Scholar 

  14. DePasquale EE, Nody AC, DePuey EG, et al. Quantitative rotational thallium-201 tomography for identifying and localizing coronary artery disease.Circulation 1988; 77: 316–327.

    Google Scholar 

  15. Nuyts J, Mortelmans L, Suetens P, et al. Model-based quantification of myocardial perfusion images from SPECT.J Nucl Med 1989; 30: 1992–2001.

    Google Scholar 

  16. Cauvin JC, Boire JY, Maublant JC, et al. Automatic detection of the left ventricular myocardium long axis and center in thallium-201 single photon emission computed tomography.Eur J Nucl Med 1992; 19: 1032–1037.

    Google Scholar 

  17. Germano G, Kavanagh PB, Chen J, et al. Operator-less processing of myocardial perfusion SPECT studies.J Nucl Med 1995; 36: 2127–2132.

    Google Scholar 

  18. Miller TD, Christian TF, Hopfenspirger MR, et al. Infarct size after acute myocardial infarction measured by quantitative tomographic99mTc sestamibi imaging predicts subsequent mortality.Circulation 1995; 92: 334–341.

    Google Scholar 

  19. Machecourt J, Longère P, Fagret D, et al. Prognostic value of thallium-201 single-photon emission computed tomographic myocardial perfusion imaging according to extent of myocardial defect.J Am Coll Cardiol 1994; 23: 1096–1106.

    Google Scholar 

  20. O'Connor MK, Hammell T, Gibbons RJ. In vitro validation of a simple tomographic technique for estimation of percentage myocardium at risk using methoxyisobutyl isonitrile technetium 99m (sestamibi).Eur J Nucl Med 1990; 17: 69–76.

    Google Scholar 

  21. Prigent F, Maddahi J, Garcia EV, et al. Quantification of myocardial infarct size by thallium-201 single-photon emission computed tomography: experimental validation in the dog.Circulation 1986; 74: 852–861.

    Google Scholar 

  22. Caldwell JH, Williams DL, Hamilton GW, et al. Regional distribution of myocardial blood flow measured by single-photon emission tomography: comparison with in vitro counting.J Nucl Med 1982; 23: 490–495.

    Google Scholar 

  23. Holman BL, Moore SC, Shulkin PM, et al. Quantitation of perfused myocardial mass using Tl-201 and emission computed tomography.Invest Radiol 1983; 18: 322–326.

    Google Scholar 

  24. Garcia EV, Cooke CD, Van Train KF, et al. Technical aspects of myocardial SPECT imaging with technetium-99m sestamibi.Am J Cardiol 1990; 66: 23E-31E.

    Google Scholar 

  25. Somsen GA, Borm JJJ, de Milliano PAR, et al. Quantitation of myocardial iodine-123 MIBG uptake in SPET studies: a new approach using the left ventricular cavity and a blood sample as a reference.Eur J Nucl Med 1995; 22: 1149–1154.

    Google Scholar 

  26. Eisner RL, Tamas MJ, Cloninger K, et al. Normal SPECT thallium-201 bull's-eye display: gender differences.J Nucl Med 1988: 29: 1901–1909.

    Google Scholar 

  27. Cohen M, Touzery C, Cottin Y, et al. Quantitative myocardial thallium single-photon emission computed tomography in normal women: demonstration of age-related differences.Eur J Nucl Med 1996; 23: 25–30.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Benoit, T., Vivegnis, D., Foulon, J. et al. Quantitative evaluation of myocardial single-photon emission tomographic imaging: application to the measurement of perfusion defect size and severity. Eur J Nucl Med 23, 1603–1612 (1996). https://doi.org/10.1007/BF01249623

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01249623

Key words

Navigation