Dilatation Mechanism of Balloon Angioplasty in Children: Assessment by Angiography and Intravascular Ultrasound

  • Published:
CardioVascular and Interventional Radiology Aims and scope Submit manuscript

Abstract

Purpose: Little information is available about the dilatation mechanism in children. This prospective study aimed to (1) evaluate the dilatation mechanism of balloon angioplasty in children with arterial stenosis, and (2) compare the morphological changes seen by intravascular ultrasound (IVUS) and angiography.

Methods: Twenty consecutive patients, who had undergone a total of 23 procedures, were examined before and immediately after balloon angioplasty with a 4.3 Fr, 30 MHz rotational tip IVUS system. The lesions for IVUS study had resulted from coarctation of the aorta in six patients, pulmonary arterial stenosis in five, Blalock-Taussig shunt stenosis in three, subclavian artery stenosis in two, renal artery stenosis in two, coronary artery stenosis in one and ductus arteriosus in one.

Results: Four distinctive morphological types were identified: type I with arterial stretching, type IIa with superficial tearing, type IIb with deep intimal-medial tearing, type III with flap formation, and type IV with dissection. The diameter of the narrowest site before and after balloon angioplasty increased significantly from 2.1 ± 1.4 mm to 4.6 ± 3.4 mm (p < 0.001). Eighteen of the 23 angioplasty procedures (78%) were considered to be successful, with a dilatation ratio of more than 50%. In most patients with successful dilatation, non-stretch mechanisms such as tearing, flap formation, or dissection were found. The positive percent (70%) of non-stretch mechanisms seen by IVUS was significantly higher than the positive findings (39%) by angiography (Χ2= 6.47, p < 0.02).

Conclusions: Non-stretch morphology of the arterial wall may be a common mechanism of dilatation after balloon angioplasty in children with arterial stenosis. IVUS is a useful modality for evaluating the effectiveness of balloon angioplasty and the mechanism of dilatation in individual cases.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ino, T., Kishiro, M., Okubo, M. et al. Dilatation Mechanism of Balloon Angioplasty in Children: Assessment by Angiography and Intravascular Ultrasound. Cardiovasc Intervent Radiol 21, 102–108 (1998). https://doi.org/10.1007/s002709900224

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002709900224

Navigation