Readers' commentCalibration using angiographic catheters as scaling devices — Importance of filming the catheters not filled with contrast medium
References (8)
- et al.
Pitfalls in the determination of absolute dimensions using angiographic catheters as calibration devices in quantitative coronary angiography
Am J Cardiol
(1991) - et al.
Assessment of dimensions and image quality of coronary contrast catheters from cineangiograms
Cath Cardiovasc Diag
(1985) - et al.
Quality control in performing quantitative angiography
Am J Cardiac Imag
(1989) - et al.
Prevention of restenosis after percutaneous transluminal coronary angioplasty with thromboxane A2 receptor blockade. A randomized double blind, placebo controlled trial
Circulation
(1991)
There are more references available in the full text version of this article.
Cited by (43)
Geographical miss and restenosis during catheter-based intracoronary β-radiation for de novo lesions
2002, Cardiovascular Radiation MedicineVisual assessment of procedural results following treatment with Sr-90 β-radiation for instent restenosis
2002, Cardiovascular Radiation MedicineGeographical miss during catheter-based intracoronary beta-radiation: Incidence and implications in the BRIE study
2001, Journal of the American College of CardiologyCitation Excerpt :Calibration of the system was based on dimensions of the catheters not filled with contrast. This method of analysis has been previously validated (18–20). The following QCA parameters were computed in the VS: computer-defined minimal luminal diameter, reference diameter obtained by an interpolated method and percentage diameter stenosis.
Methodological and clinical implications of the relocation of the minimal luminal diameter after intracoronary radiation therapy
2000, Journal of the American College of CardiologyCitation Excerpt :Calibration of the system was based on dimensions of the catheters unfilled with contrast medium. This method of analysis has been previously validated (4,15,16). The area of interest was selected after reviewing all cinefilms performed during the index procedure.
Periprocedural quantitative coronary angiography after Palmaz-Schatz stent implantation predicts the restenosis rate at six months: Results of a meta-analysis of the Belgian Netherlands Stent study (BENESTENT) I, BENESTENT II pilot, BENESTENT II and MUSIC trials
1999, Journal of the American College of CardiologyQuantitative angiographic comparison of elastic recoil after coronary excimer laser-assisted balloon angioplasty and balloon angioplasty alone
1995, Journal of the American College of Cardiology
Copyright © 1992 Published by Elsevier Inc.