Results of anterograde transcatheter closure of patent ductus arteriosus using single or multiple gianturco coils
References (14)
- et al.
Transcatheter closure of patent ductus arteriosus in pediatric patients
J Pediatr
(1989) - et al.
Results of transcatheter closure of the patent ductus arteriosus with the Botalloocluder
J Am Coll Cardiol
(1993) - et al.
Percutaneous closure of the small patent ductus arteriosus using occluding spring coils
J Am Coll Cardiol
(1994) - et al.
Angiographic classification of the isolated, persistently patent ductus arteriosus and implications for percutaneous catheter occlusion
Am J Cardiol
(1989) - et al.
Patent ductus arteriosus in adults—long-term follow-up: nonsurgical versus surgical treatment
J Am Coll Cardiol
(1986) - et al.
Transcatheter closure of a patent ductus arteriosus: successful use in a 3.5 kg infant
Pediatr Cardiol
(1979) - et al.
Non-surgical closure of patent ductus arteriosus: clinical application of the Rashkind PDA occluder system
Circulation
(1987)
There are more references available in the full text version of this article.
Cited by (222)
Percutaneous Closure of Patent Ductus Arteriosus in Infants 1.5 kg or Less: A Meta-Analysis
2021, Journal of PediatricsTranscatheter Echocardiographic-Guided Closure of Patent Ductus Arteriosus in Extremely Premature Newborns
2016, JACC: Cardiovascular InterventionsBiomaterials and design in occlusion devices for cardiac defects: A review
2014, Acta BiomaterialiaCitation Excerpt :Although the Gianturco device has never undergone formal FDA approval, it is available for clinical use. Subsequently, a number of modifications of the coil and refinements of the coil implantation procedure have been done, including multiple Gianturco coils [98], tapered tip catheters for coil delivery [99], increasing the diameter of the wires of Gianturco coils [100], Cook detachable coils [101,102], GGVODs [103] and five-loop coils [104]. Aside from these, the Nit-Occlud™ coil [105] has a biconical shape that is more suitable to the conical shape of most patent ductus than normal cylindrical Gianturco coils; this is currently available outside the USA.
Estimation of patent ductus arteriosus diameters by colour Doppler echocardiography in children
2010, Cardiology in the YoungInterventional procedures
2018, Right Heart Pathology: From Mechanism to ManagementComplications of transcatheter closure in patent ductus arteriosus patients
2017, International Cardiovascular Research Journal
Copyright © 1994 Published by Elsevier Inc.