Simulation of intraoperative visualization of cardiac structures and study of dynamic surgical anatomy with real-time three-dimensional echocardiography

https://doi.org/10.1016/0002-9149(94)90682-3Get rights and content

Abstract

Most prior efforts of 3-dimensional (3-D) reconstruction of echocardiographic images have focused on quantitation of ventricular size and function. The resulting images have been displayed in the wire mesh format. Recently, a method for 3-D transesophageal echocardiography using a computer-controlled probe that acquires parallel tomographic slices has been described. This technique provides dynamic 3-D volume-rendered images of the heart. This study was designed to determine if surgical visualization of intracardiac anatomy could be simulated using this imaging system. Data acquired from 8 patients with congenital and acquired heart disease were analyzed. Real-time 3-D images of the cardiac chambers and valves were obtained. Images of the cardiac pathology including fibrocalcific nodules on the aortic valve, mitral valve endocarditis, rheumatic mitral stenosis, and an ostium secundum atrial septal defect were displayed in 3 dimensions that simulated surgical exposure of these structures. These 3-D representations of cardiac anatomy were in some ways superior to standard intraoperative visualization in that they demonstrated the heart as a dynamic structure, as opposed to the empty, non-beating heart observed while on cardiopulmonary bypass. In conclusion, 3-D images of cardiac structures as seen by the surgeon intraoperatively can be provided using a computer-driven tomographic transesophageal echocardiographic probe. This imaging system can be potentially useful in the planning and evaluation of cardiac surgery. Technical improvements such as 3-D representation of flow jets, the ability to manipulate images to simulate cardiac surgery, and on-line reconstruction can make this a Dowerful tool in the future.

References (24)

  • M. Belohlavek et al.

    Three- and four-dimensional cardiovascular ultrasound imaging: a new era for echocardiography

  • H.A. McCann et al.

    Multidimensional ultrasonic imaging for cardiology

  • Cited by (135)

    • Intraoperative Echocardiography in Mitral Valve Repair

      2008, Practice of Clinical Echocardiography, Thrid Edition
    • The Evaluation of Real-time 3-Dimensional Transthoracic Echocardiography for the Preoperative Functional Assessment of Patients with Mitral Valve Prolapse: A Comparison with 2-Dimensional Transesophageal Echocardiography

      2007, Journal of the American Society of Echocardiography
      Citation Excerpt :

      A 3D presentation of the mitral valve is highly desirable to the surgeon for planning surgery. Reconstruction of the mitral valve en face from the LA side provides a view of the valve similar to that seen intraoperatively by the cardiac surgeon, with an additional advantage of displaying the dynamic motion of the valve within the beating heart.23 Earlier studies have suggested that 3D-TEE was feasible but not superior to 2D-TEE for precise anatomic localization of prolapsing mitral valve segments.4,5,24,25

    View all citing articles on Scopus
    View full text