Elsevier

The Annals of Thoracic Surgery

Volume 58, Issue 6, December 1994, Pages 1609-1613
The Annals of Thoracic Surgery

Original article
One-incision approach for insertion of implantable cardioverter defibrillators

https://doi.org/10.1016/0003-4975(94)91643-8Get rights and content

Abstract

The placement of a transvenous implantable cardioverter defibrillator (ICD) system through a single infraclavicular skin incision has been a surgical goal for years. The development of a new investigational model of ICD with substantially reduced dimensions (volume, 83 cm3; mass, 132 g) has made the one-incision approach a clinical reality. Between March and September 1993, 4 female and 19 male patients (mean age, 60 ± 9.6 years; range, 46 to 73 years) underwent implantation of this device for the treatment of ventricular fibrillation (n = 14) or ventricular tachycardia (n = 9). One transvenous lead was placed in the right ventricular apex and another in the left subclavian vein. A subpectoral pocket was formed in the infraclavicular area from the same incision to house the ICD generator and, if necessary, the subcutaneous patch. The mean operation time (81.5 ± 32.7 minutes; range, 54 to 195 minutes) was significantly shorter than that noted for a previous series made up of patients undergoing traditional transvenous ICD implantations. In 20 patients (87%), endovenous defibrillation without a subcutaneous patch successfully caused externally induced ventricular fibrillation to revert with a mean minimum energy output of 21.9 ± 3.5 J (range, 12 to 24 J). Endovenous defibrillation was more successful when biphasic (n = 16/17 [94%]) shocks rather than monophasic shocks (n = 4/6 [67%]) were used. No mortality, morbidity, or surgical complications were observed. These results indicate that the one-incision approach and the small size of the ICD generator can substantially facilitate ICD implantation and result in a reduction in the surgical trauma, the operation time, and the amount of material implanted.

References (17)

  • L Watkins et al.

    Automatic defibrillation in man: the initial surgical experience

    J Thorac Cardiovasc Surg

    (1981)
  • L Watkins et al.

    Implantation of the automatic defibrillator: the subxiphoid approach

    Ann Thorac Surg

    (1982)
  • M Mirowski et al.

    Termination of malignant ventricular arrhythmias with an implanted automatic defibrillatc in human beings

    N Engl J Med

    (1980)
  • S Nisam et al.

    Patient survival comparison in three generations of automatic implantable cardioverter defibrillators: review of 12 years, 25000 patients

    PACE

    (1993)
  • GM Lawrie et al.

    Epicardial implantation of the automatic implantable defibrillator by left subcostal thoracotomy

    PACE

    (1984)
  • R Frame et al.

    Initial experience with transvenous implantable cardioverter defibrillator lead systems: operative Morbidity and mortality

    PACE

    (1993)
  • S Saksena et al.

    Defibrillation thresholds and perioperative mortality associated with endocardial and epicardial defibrillation lead systems

    PACE

    (1993)
  • W Grimm et al.

    Complications of implantable cardioverter defibrillator therapy: follow-up of 241 patients

    PACE

    (1993)
There are more references available in the full text version of this article.

Cited by (19)

  • ICDs, VT, VF, and the AATS and STS

    1994, The Annals of Thoracic Surgery
View all citing articles on Scopus
View full text