Elsevier

Annals of Emergency Medicine

Volume 18, Issue 12, December 1989, Pages 1269-1275
Annals of Emergency Medicine

Special contribution
From concept to standard-of-care? Review of the clinical experience with automated external defibrillators

https://doi.org/10.1016/S0196-0644(89)80257-4Get rights and content

There is now both national and international acceptance of the “principle of early defibrillation,” which contends that whoever arrives first at the scene of a cardiac arrest should have a defibrillator. The almost revolutionary technological event that permits widespread implementation of this principle has been the development of automated external defibrillators (AEDs). The simplicity, accuracy, and safety of these devices markedly expands the range of people who can deliver early defibrillation, which includes minimally trained emergency personnel, lay and community responders, and family members of high-risk patients. Even though AEDs now approach the status of “standard of care,” the AED, as an example of a new technology, has not followed the classic technology paradigm: conceptualization, experimentation, dissemination, and standard of care. Instead, like many other technical innovations in emergency medicine, the development of AEDs proceeded simultaneously on many fronts, and implementation often occurred before confirmation of important subissues. AEDs may experience the life cycle of many new ideas: initial enthusiasm and widespread adoption, followed by disillusionment and rejection, and finally a mature, proper perspective. Careful implementation and continued evaluation may help emergency personnel avoid periods of disillusionment with AEDs and move steadily and uneventfully to a proper perspective.

References (46)

  • BantaHD

    Embracing or rejecting innovations: Clinical diffusion of health care technology

  • CumminsRO et al.

    A new rhythm library for testing automatic external defibrillators: Performance of three devices

    J Am Coll Cardiol

    (1988)
  • MurphyDM

    Rapid defibrillation: Fire service to lead the way

    J Emerg Med Serv

    (1987)
  • VukovLF et al.

    New perspectives on rural EMT defibrillation

    Ann Emerg Med

    (1988)
  • WeaverWD et al.

    Use of the automatic external defibrillator in the management of out-of-hospital cardiac arrest

    N Engl J Med

    (1988)
  • NewmanM

    American Heart Association Task Force takes action: Curriculum created for early defibrillation

    J Emerg Med Serv

    (1989)
  • BantaHD et al.

    Toward Rational Technology in Medicine

  • ThackerSB

    Meta-analysis: A quantitative approach to research integration

    JAMA

    (1988)
  • DelunaAB et al.

    Ambulatory sudden cardiac death: Mechanism of production of fatal arrhythmia on the basis of data from 157 cases

    Am Heart J

    (1989)
  • EisenbergMS

    Who shall live? Who shall die?

  • WeaverWD et al.

    Factors influencing survival after out-of-hospital cardiac arrest

    J Am Coll Cardiol

    (1986)
  • EisenbergMS et al.

    Treatment of out-of-hospital cardiac arrest with rapid defibrillation by emergency medical technicians

    N Engl J Med

    (1980)
  • StultsKR et al.

    Prehospital defibrillation performed by emergency medical technicians in rural communities

    N Engl J Med

    (1984)
  • DiackAW et al.

    An automatic cardiac resuscitator for emergency treatment of cardiac arrest

    Med Instr

    (1979)
  • JaggaraoNS et al.

    Use of an automated external defibrillator-pacemaker by ambulance staff

    Lancet

    (1982)
  • CumminsRO et al.

    The sensitivity, accuracy and effectiveness of an automatic external defibrillator: Report of a field evaluation by paramedics

    Lancet

    (1984)
  • WeaverWD et al.

    Cardiac arrest treated with a new automatic external defibrillator by out-of-hospital first responders

    Am J Cardiol

    (1986)
  • GrayAJ et al.

    Use of the automatic external defibrillator-pacemaker by ambulance personnel: The Stockport experience

    Br Med J

    (1987)
  • RozkovecA et al.

    Safety and effectiveness of a portable external automatic defibrillator-pacemaker

    Clin Cardiol

    (1983)
  • AronsonAL et al.

    The automatic defibrillator-pacemaker: Clinical rational and engineering design

    Med Instr

    (1986)
  • StultsKR et al.

    Self-adhesive monitor-defibrillator pads improve prehospital defibrillation success

    Ann Emerg Med

    (1987)
  • KerberRE et al.

    Use of the tongue as a site for defibrillation: Impedance characteristics of vertical shock pathways in humans

    Circulation

    (1983)
  • WeaverWD et al.

    Automatic external defibrillators: Importance of field testing to evaluate performance

    J Am Coll Cardiol

    (1987)
  • Cited by (141)

    • A simulation study to improve the performance of an emergency medical service: Application to the French Val-de-Marne department

      2014, Simulation Modelling Practice and Theory
      Citation Excerpt :

      These two metrics are of critical importance because they are related to the primary objective of the SAMU systems, which is saving lives while limiting the cost of operations. The association between high coverage and the high survival rate of patients has been noted by several authors in the literature especially in the case of life-threatening emergencies [1–5]. For instance, the likelihood of survival from cardiac arrest decreases by 7–10% for each minute of delay in response time [6].

    View all citing articles on Scopus

    Presented at the SAEM-IRIEM Research Symposium in Fort Lauderdale, Florida, February 1989.

    View full text