Increase in ventricular tachycardia frequency after biventricular implantable cardioverter defibrillator upgrade

J Cardiovasc Electrophysiol. 2003 Nov;14(11):1245-7. doi: 10.1046/j.1540-8167.2003.03303.x.

Abstract

We report the case of a patient in whom transvenous left ventricular pacing lead placement at the time of a biventricular upgrade led to an exacerbation of clinical monomorphic ventricular tachycardia (MVT). At implant, slow left ventricular pacing repeatedly induced sustained MVT. However, testing of the biventricular pacing showed no MVT inducibility, and the system was implanted. The patient was readmitted due to multiple episodes of the MVT observed at implant. The MVT was controlled with pharmacotherapy, allowing the patient to continue with biventricular pacing.

Publication types

  • Case Reports

MeSH terms

  • Amiodarone / therapeutic use
  • Anti-Arrhythmia Agents / therapeutic use
  • Cardiac Pacing, Artificial / adverse effects*
  • Cardiac Pacing, Artificial / methods*
  • Defibrillators, Implantable / adverse effects*
  • Humans
  • Male
  • Middle Aged
  • Tachycardia, Ventricular / drug therapy
  • Tachycardia, Ventricular / etiology*
  • Tachycardia, Ventricular / therapy*
  • Treatment Failure