Restenosis after successful percutaneous transluminal coronary angioplasty: serial angiographic follow-up of 229 patients

J Am Coll Cardiol. 1988 Sep;12(3):616-23. doi: 10.1016/s0735-1097(88)80046-9.

Abstract

To further understand the temporal mode and mechanisms of coronary restenosis, 229 patients were studied by prospective angiographic follow-up on day 1 and at 1, 3 and 6 months and 1 year after successful percutaneous transluminal coronary angioplasty. Quantitative measurement of coronary stenosis was achieved by cinevideodensitometric analysis. Actuarial restenosis rate was 12.7% at 1 month, 43.0% at 3 months, 49.4% at 6 months and 52.5% at 1 year. In 219 patients followed up for greater than or equal to 3 months, mean stenosis diameter was 1.91 +/- 0.53 mm immediately after coronary angioplasty, 1.72 +/- 0.52 mm on day 1, 1.86 +/- 0.58 mm at 1 month and 1.43 +/- 0.67 mm at 3 months. In 149 patients followed up for greater than or equal to 6 months, mean stenosis diameter was 1.66 +/- 0.58 mm at 3 months and 1.66 +/- 0.62 mm at 6 months. In 73 patients followed up for 1 year, mean stenosis diameter was 1.65 +/- 0.56 mm at 6 months and 1.66 +/- 0.57 mm at 1 year. Thus, stenosis diameter decreased markedly between 1 month and 3 months after coronary angioplasty and reached a plateau thereafter. In conclusion, restenosis is most prevalent between 1 and 3 months and rarely occurs beyond 3 months after coronary angioplasty.

MeSH terms

  • Aged
  • Angioplasty, Balloon*
  • Coronary Angiography*
  • Coronary Disease / diagnostic imaging*
  • Coronary Disease / pathology
  • Coronary Vessels / pathology
  • Female
  • Follow-Up Studies
  • Humans
  • Male
  • Middle Aged
  • Recurrence