Ventricular tachycardia during follow-up in patients resuscitated from ventricular fibrillation: experience from stored electrograms of implantable cardioverter-defibrillators

J Am Coll Cardiol. 1998 Nov 15;32(6):1724-30. doi: 10.1016/s0735-1097(98)00430-6.

Abstract

Objective: The purpose of this study was to use the electrogram storage capabilities of the implantable cardioverter-defibrillator (ICD) to categorize any arrhythmic event during follow-up in a group of patients who had survived an episode of ventricular fibrillation (VF) and to possibly identify clinical predictors of future arrhythmic events.

Background: Little is known about the electrophysiologic characteristics of ventricular arrhythmias recurring during follow-up in survivors of VF as the sole documented arrhythmia at the time of resuscitation.

Methods: Forty patients (58+/-10 years; 73% men; left ventricular ejection fraction 42+/-18%; 70% with coronary artery disease) who had survived an episode of VF and subsequently received an ICD capable of intracardiac electrogram recording and storage were followed for 23+/-11 months. In all patients, the arrhythmogenic substrate was investigated by means of programmed electrical stimulation (PES).

Results: Among the 40 patients, 41 episodes of ventricular arrhythmias were documented in 13 patients (33%): 36 episodes of ventricular tachycardias (VT) were recorded in 11 patients (28%) and 5 episodes of VF were recorded in the remaining 2 patients (5%). Age, gender, cardiac disease and left ventricular ejection fraction failed to distinguish between patients with clinical recurrences and patients without. The sensitivity, specificity and positive accuracy of PES were 29%, 63% and 46%, respectively, for prediction of ventricular arrhythmia recurrence; 45%, 70% and 36%, respectively, for prediction of VT; and 50%, 98% and 50%, respectively, for prediction of VF during follow-up.

Conclusions: In survivors of VF receiving ICD therapy, VT is the most common ventricular arrhythmia recorded on device-incorporated electrograms during follow-up. This finding, associated with the relatively well-preserved ventricular function, may account for the ability of these patients to survive at time of the index arrhythmia; the use of antitachycardia pacing as a modality to treat arrhythmia recurrences may contribute to reduce the incidence of shock during follow-up in these patients.

MeSH terms

  • Aged
  • Arrhythmias, Cardiac / diagnosis
  • Arrhythmias, Cardiac / etiology
  • Arrhythmias, Cardiac / physiopathology
  • Cardiac Pacing, Artificial
  • Defibrillators, Implantable*
  • Electrocardiography / instrumentation
  • Female
  • Follow-Up Studies
  • Humans
  • Male
  • Middle Aged
  • Postoperative Complications*
  • Predictive Value of Tests
  • Recurrence
  • Resuscitation*
  • Tachycardia, Ventricular / diagnosis
  • Tachycardia, Ventricular / etiology*
  • Tachycardia, Ventricular / physiopathology
  • Ventricular Fibrillation / surgery
  • Ventricular Fibrillation / therapy*