Article Text

Download PDFPDF
Self expandable stents for relief of venous baffle obstruction after the Mustard operation
  1. S C Browna,
  2. B Eyskensa,
  3. L Mertensa,
  4. L Stockxb,
  5. M Dumoulina,
  6. M Gewilliga
  1. aPaediatric Cardiology, University Hospital Gasthuisberg, Leuven, Belgium, bRadiology
  1. Professor Dr M Gewillig, Paediatric Cardiology, University Hospitals Leuven, B 3000, Leuven, Belgium.

Abstract

Objective Obstruction of the venous pathways after Mustard repair for transposition of the great arteries is associated with an increased risk of arrhythmia and sudden death. The purpose of this study was to assess the effectiveness of the largest (tracheal 22 × 40 mm) Wallstents in treating baffle obstructions.

Design Retrospective analysis of patients with stented venous pathways.

Subjects Eleven patients with baffle obstruction after Mustard repair for transposition of the great arteries.

Interventions Stenoses were dilated with an 18 or 20 mm balloon. However, recoil was noticed in 11 patients: immediately (n = 7) or on repeat angiography (n = 4). Eighteen stents were implanted (mean (SD)) 18 (3.3) years postoperatively. After dilatation a tracheal Wallstent (11.5 F) was deployed.

Main outcome measures Relief of obstruction, haemodynamic improvement.

Results In the inferior vena cava, 10 stents were deployed in seven baffle obstructions with an increase in diameter from 9.8 (2.4) mm to 16.5 (1.4) mm (p < 0.01) and a mean (SD) pressure gradient decrease from 5.1 (3.6) mm Hg to 1.4 (2.0) mm Hg; in the superior vena cava, eight stents were implanted increasing the diameter from 9.1 (3.7) mm to 15.6 (3.8) mm (p < 0.001) with a decrease in mean pressure gradient from 5.1 (2.7) mm Hg to 1.9 (1.5) mm Hg. No complications were experienced during implantation. No anticoagulation was prescribed. During follow up (1.7 (0.6) years; range, 0.9–2.6) no problems were noted; five patients were re-catheterised without change in measurements. There was no evidence of peal formation in any of the stents.

Conclusion It is concluded that Wallstents are safe, easy to use, and effective in relieving baffle obstruction. Anticoagulation does not seem neccessary.

  • Mustard procedure
  • venous baffle obstruction
  • stent

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.