Article Text

Download PDFPDF
Heart rhythm disorders and pacemakers
Clinical predictors of cardiac syncope at initial evaluation in patients referred urgently to a general hospital: the EGSYS score
  1. A Del Rosso1,
  2. A Ungar2,
  3. R Maggi3,
  4. F Giada4,
  5. N R Petix1,
  6. T De Santo5,
  7. C Menozzi6,
  8. M Brignole3
  1. 1
    Department of Cardiology, Azienda USL 11 Empoli, Italy
  2. 2
    Department of Geriatric Medicine and Cardiology, Università degli Studi di Firenze, Firenze, Italy
  3. 3
    Department of Cardiology, Ospedali del Tigullio, Lavagna, Italy
  4. 4
    Department of Cardiology, Ospedale Umberto I, Mestre, Italy
  5. 5
    Fondazione Medtronic, Roma, Italy
  6. 6
    Department of Cardiology, Ospedale S Maria Nuova, Reggio Emilia, Italy
  1. Dr A Del Rosso, via F Cairoli 21, 50053 Vinci (FI), Italy; elettrofisiologia{at}usl11.tos.it

Abstract

Objective: To develop, in patients referred for syncope to an emergency department (ED), a diagnostic score to identify those patients likely to have a cardiac cause.

Design: Prospective cohort study.

Setting: ED of 14 general hospitals.

Patients: 516 consecutive patients with unexplained syncope.

Interventions: Subjects underwent a diagnostic evaluation on adherence to Guidelines of the European Society of Cardiology. The clinical features of syncope were analysed using a standard 52-item form. In a validation cohort of 260 patients the predictive value of symptoms/signs was evaluated, a point score was developed and then validated in a cohort of 256 other patients.

Main outcome measurements: Diagnosis of cardiac syncope, mortality.

Results: Abnormal ECG and/or heart disease, palpitations before syncope, syncope during effort or in supine position, absence of autonomic prodromes and absence of predisposing and/or precipitating factors were found to be predictors of cardiac syncope. To each variable a score from +4 to –1 was assigned to the magnitude of regression coefficient. A score ⩾3 identified cardiac syncope with a sensitivity of 95%/92% and a specificity of 61%/69% in the derivation and validation cohorts, respectively. During follow-up (mean (SD) 614 (73) days) patients with score ⩾3 had a higher total mortality than patients with a score <3 both in the derivation (17% vs 3%; p<0.001) and in the validation cohort (21% vs 2%; p<0.001).

Conclusions: A simple score derived from clinical history can be usefully employed for the triage and management of patients with syncope in an ED.

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes

  • Funding: This study was supported by a grant from Gruppo Italiano per lo Studio della Sincope (GIMSI).

  • Competing interests: Declared. TDS is an employee of Medtronic Italia. The other authors have no conflict of interest.

  • Ethics approval: Ethics committee approval received.

  • Contributors: The following people participated in the EGSYS-2 study. Steering Committee: F Ammirati, M Brignole, I Casagranda, P Cortelli, M Disertori, R Furlan, F Giada, I Iori, A Lagi, M Lunati, G Mathieu, C Menozzi, G Miceli, C Mussi, P Ponzi, A Raviere, G Re, MA Ribani, G Sandrone, A Scivales and A Ungar. A list of participating centres and investigators is reported elsewhere.3

Linked Articles